STERIS Certified Pre-Owned Medivators ADVANTAGE PLUS Automated Endoscope Reprocessor
STERIS Corporation - Helping to provide a healthier today and a safer tomorrow.

STERIS Certified Pre-Owned Medivators ADVANTAGE PLUS™ Automated Endoscope Reprocessor

  • Brand: STERIS
  • Model: ADVANTAGE PLUS™ AER
  • Key Feature: Offers automated and consistent cleaning of flexible endoscopes
  • Clinical Application: Provides high-level disinfection to support infection prevention

Product Overview

The STERIS Certified Pre-Owned ADVANTAGE PLUS Automated Endoscope Reprocessors (AER) provide high-level disinfection cycles and asynchronous programmable systems. The ADVANTAGE PLUS AER aids in standardizing endoscope reprocessing, offering cycles to clean and disinfect flexible endoscopes. Its ergonomic design is intended to aid high-functioning teams and demanding facilities to reduce cross-contamination and human error.

  • Monitors endoscope channels for blockage
  • Ensures high-level disinfectant is delivered to all channels
  • Automated cycle eliminates the variability of manual cleaning
  • Validated cleaning claim enhances endoscope reprocessing
  • Leak test enables disinfection of leaky endoscopes prior to repair
  • Automated alcohol flush facilitates drying of endoscope channels
  • Barcode reader for fast and accurate data entry
  • Remote diagnostics for efficient servicing
  • Computerized cycle documentation and reporting. The ADVANTAGE PLUS integrates with the SPM® Surgical Asset Tracking Software and other tracking software for active monitoring and process verification

STERIS Certified Pre-Owned (CPO) MEDIVATORS™ Automated Endoscope Reprocessors (AERs) undergo a precise STERIS certification process. STERIS CPO technicians thoroughly inspect and refurbish each unit to ensure each MEDIVATORS AER meets STERIS specifications to be like-new aesthetically and operationally.

Disclaimer:

  • The STERIS Certified Pre-Owned Equipment program is offered solely by STERIS and is not affiliated with, endorsed by, or supported by other Original Equipment Manufacturers (OEMs). STERIS Certified Pre-Owned Equipment is refurbished by STERIS.
  • Product specifications and information could differ depending on the manufacturer, date of manufacture, product series, or model or as determined by the Original Equipment Manufacturer (OEM) and are subject to change. As a reseller of pre-owned equipment, STERIS refurbishes to any known or available performance characteristics for the specific series or model of the product. All Certified Pre-Owned Equipment undergoes a multi-point functionality inspection and is certified to meet STERIS Certified Pre-Owned Equipment Refurbishing Program standards.
  • STERIS Certified Pre-Owned Equipment may or may not include OEM resource materials (e.g., instruction manuals, guides, and other documentation) or OEM parts.
  • For warranty information, please see: STERIS Certified Pre-Owned Equipment Warranty
  • Operations located in North America; STERIS Certified Pre-Owned Equipment is intended for sale within the Americas.
Go to Top of Page
 

Specifications

FEATURE DESCRIPTION
Dimensions
  • 59 H x 45 W x 36 D" (150 H x 114 W x 92 D cm)
  • Lid Height: Open – 54" (137 cm), Closed – 38" (97 cm)
  • Depth with air compressor: 37.5 “ (95.cm)
Weight
  • 400 lbs. (182 kg)
Electrical Requirements
  • 100-240 VAC ± 10%: single phase, 50/60HZ; 1000 Watts
Electrical Safety Certifications
  • ETL Intertek Listed #75811
  • UL Standard 61010-1
  • EN Standard 61010-1
  • CSA/CAN Standard C22.2, No. 61010-1
Water Supply Requirements
  • Minimum flow rate: 1.32 GPM (5 LPM) at 35 to 87 PSI (2.4 to 6 bar)
  • Water Temperature: (35º C ± 2º C) - North America; (25º C ± 2ºC) – International
  • Water Hardness: less than 12 gpg (200 ppm)
  • Pre-filter wall space: 26 H x 38 W x 6 D" (66 H x 96 W x 15 D cm)
Basin Size
  • 19 W x 17 L x 7 D" (48 H x 43 L x 18 D cm)
Go to Top of Page
 

STERIS Certification Process

Medivators AERs from STERIS CPO are refurbished products that undergo precise STERIS certification process. STERIS CPO technicians thoroughly inspect and refurbish each unit to meet STERIS specifications to be like-new aesthetically and operationally.

Diagnostics/Inspections

Through this step STERIS CPO technicians ensure quality and adherence to OEM standards, committed to preserving equipment reliability. Our program conducts a series of thorough inspections.

  • Inspect the unit for leaks
  • Verify Leak Tester option functionality
  • Verify the operation of the GFI outlet
  • Verify adjustment of drain times
  • Extensive cycle validation to ensure functionality
  • Check the unit for proper labeling and clean area. Wipe down the unit.
  • Open all valves and allow water to escape all valves and no pooling water

Conditional Replacement/Refurbishment

STERIS CPO refurbishes each Medivators AER to meet the OEM performance and quality standards. Our AER Certification Process restores equipment as an all-encompassing service.

  • Rebuild all valves
  • Replace valve seals
  • Replace filters
  • Replace disinfection pump
  • Replace the scanner and monitor
  • Replace damaged, discolored, or stained plastic exterior components
  • Rebuild the SSG unit
  • Replace tubing and hoses
  • Replace dosing pumps
  • Replace o-rings on pumps, dosing reservoirs, and drain manifold
  • Replace springs and rubber balls on dosing reservoirs
  • Replace the squeeze tube for the alcohol and detergent delivery pump
Go to Top of Page
 