V-PRO™ s2 Low Temperature Sterilization System
- Capacity - Process up to 25lbs in 28 minutes, or 4 lbs in as quick as 19 minutes
- Features - Small footprint at less than 2 feet wide easily fits in space constrained departments
- Compatibility - Compatible with the widest range of medical devices and materials
Product Overview
The V-PRO s2 Low Temperature Sterilizer delivers the right cycles to meet your Sterile Processing Departments' (SPD) demands while fitting in the tightest spaces of your facility at just 22 ½" wide. This compact, low temperature sterilizer also offers a 19-minute cycle for quick turnaround of devices. Delivering maximum productivity.
How the V-PRO s2 Low Temperature Sterilization System Works
The V-PRO s2 Low Temperature Sterilization System is a vaporized hydrogen peroxide (VH2O2) sterilizer that uses VAPROX™ HC Sterilant and provides terminal sterilization of properly prepared (cleaned, rinsed, and dried) medical devices. This compact sterilizer offers pre-programmed cycles that operate at low temperatures, processing medical devices without leaving toxic residues. Pre-programmed cycles include:
| Cycle | Lumen† |
Non Lumen |
Flexible† |
Fast† |
|---|---|---|---|---|
|
†Refer the operator manual for lumen size limitations. *da Vinci is a registered trademark of Intuitive Surgical, Inc. |
||||
| Cycle Time | 60 Minutes |
28 Minutes |
38 Minutes |
19 Minutes |
| Load Weight | ≤ 11lb/5 kg | ≤25 lb/11.3 kg | 1 Scope | ≤11 lb/ 5kg: 1 Scope and Non Lumened and Lumened Devices |
≤4 lb/1.8 kg, Peel Pouch Only |
| Device Examples |
|
|
|
|
Please refer to the Operator Manual for detailed lumen dimension information and how to identify devices for loads.
Why Choose the V-PRO s2 Low Temperature Sterilization System?
- Size: At just 22 ½" wide, the compact V-PRO s2 Sterilizer can easily fit into space-constrained locations.
- Throughput: Faster VH2O2 sterilization cycles and more flexibility than any other small low temperature sterilizer on the market.
- Compatibility: V-PRO Sterilizers work with the widest range possible of medical devices and materials – 87% more device materials than the leading competitor.
- Safety: Innovative foot sensor makes hands-free loading quick, safe, and easy. V-PRO Sterilizers are designed with numerous safety features, and STERIS considers established OSHA and AAMI Standards in developing our IFUs and making safety recommendations. Click Here to Learn about V-PRO Safety Features.
- Instructional Videos: The V-PRO s2 Sterilizer makes tasks more straightforward and easier to train staff and stay compliant with instructional videos available on the sterilizer screen.
Supporting Your Sustainability Goals
- Conserve Utilities – Sterilize devices with no water consumption or wastewater produced using significantly less electricity than steam sterilization - only 2.3 kWh/cycle. Sterilizer does not generate notable heat that can impact the HVAC load.
Olympus®
| Device Type | Model |
|---|---|
| Bronchoscopes | BF, such as BF1T60 |
| Cystoscopes | CYF, such as CYF V2 |
| Pleuroscope | LTF, such as LTF VH1 |
Karl Storz®
| Device Type | Model |
|---|---|
| Ureteroscope | 11278AU1 |
| Rhino Pharyngoscope | 11101RP2 |
| C-Mac Intubation Fiberscope | 11302BD2 |
| Fiberscope |
Stryker®
| Device Type | Model |
|
HD Cameras |
1488-010-000 |
Medline®
| Device Type | Model |
|---|---|
| Sterilization Wraps | Various |
Cardinal Health™
| Device Type | Model |
|---|---|
| Sterilization Wraps | Various |
Halyard Health®
| Device Type | Model |
|---|---|
| Sterilization Wraps | Various |
Visit the V-PRO Device Matrix to find out if your device can be reprocessed in a V-PRO Low Temperature Sterilization System. The Device Matrix contains information on devices from hundreds of manufacturers including:
- Aesculap
- Arthrex
- BK Ultrasound
- Brainlab
- Braun
- Cardinal Health
- Fisher & Paykel
- GE Healthcare
- Halyard Health
- Hitachi Aloka
- Intuitive Surgical
- Karl Storz
- Medline
- Medovations
- Mizuho
- Olympus
- Philips
- Richard Wolf
- St. Jude Medical
- Stryker
- Teleflex
- Truphatek
- Volk
- WelchAllyn
Connectivity and Electronic Record Management with ConnectAssure™ Technology
Seamlessly connect and get immediate results from your V-PRO s2 Low Temperature Sterilizer and Celerity Incubator with ConnectAssure Technology. ConnectAssure Technology Data Export software helps promote compliance throughout the facility by interfacing compatible STERIS products with SPM Surgical Asset Tracking Software and many of the other leading instrument tracking systems.
FAQs
What can the V-PRO s2 Low Temperature Sterilizer sterilize?
The V-PRO s2 Low Temperature Sterilizer can sterilize more than just instruments that are heat sensitive. Devices like batteries, rigid endoscopes, general stainless steel instruments, bronchoscopes, and others will benefit from short cycle times with a gentle, low temperature process.
How fast can the V-PRO s2 Low Temperature Sterilizer sterilize?
The V-PRO s2 Low Temperature Sterilizer has four cycles that range from fast to extremely fast, with all cycles starting with a moisture checking condition phase included in the total time:
- The Lumen Cycle will process rigid lumened devices in around 60 minutes
- The Flexible Cycle will process flexible scopes in around 38 minutes
- The Non Lumen Cycle will process general stainless steel and non lumened devices in around 28 minutes
- For the fastest turn-around, the Fast Cycle will process instruments and instruments in pouches or pouched trays in around 19 minutes. Please confirm that the pouches and trays are validated for the Fast Cycle.
What STERIS accessories are designed to work with the V-PRO s2 Low Temperature Sterilizer?
A wide range of products are available to be used with the V-PRO s2 Low Temperature Sterilizer:
- Celerity™ HP Biological Indicators
- Celerity™ HP Challenge Packs
- Celerity™ HP Multivariable Chemical Indicator
- VAPROX™ HC Sterilant with RFID label
- Verdoc™ Vaporized VH2O2 Record Card with Process Indicator
- PRO-LITE™ Sterilization Trays, Instrument Organizers, and Silicone Mats
- Vis-U-All™ Low Temperature Sterilization Pouches and Tubing
What is the difference between STERIS’s V-PRO Low Temperature Sterilization Systems?
Explore the differences between V-PRO Sterilizers and other common VH2O2 Sterilizers based on important factors like chamber size, cycle time, utilities, electronic record-keeping capabilities, and more using our interactive tool.
|
OPERATORS MANUAL
|
|
|---|---|
| Document # | Document Title |
| V-PRO S2 | |
| V-PRO S2 LOW TEMPERATURE STERILIZATION SYSTEM | |
| V-PRO S2 (DA) | |
| AMSCO V-PRO S2 OPERATOR MANUAL (CHINA-SPECIFIC)_ZH-CN | |
| AMSCO V-PRO S2 OPERATOR MANUAL (CHINA-SPECIFIC)_ZH-CN | |
| V-PRO S2 - GREEK (EL-GR) | |
|
TECH DATA SHEET
|
|
|---|---|
| Document # | Document Title |
| AMSCO V-PRO S2 | |
|
TECHNICAL MONOGRAPH
|
|
|---|---|
| Document # | Document Title |
| V-PRO S2 LOW TEMPERATURE STERILIZATION SYSTEM | |
| MONOGRAPHIE DES DONNÉES TECHNIQUES - SYSTÈME DE STÉRILISATION À BASSE TEMPÉRATURE V-PRO S2 | |
|
INSTRUCTIONS FOR USE
|
|
|---|---|
| Document # | Document Title |
| AMSCO V-PRO CHAMBER CLEANING IFU | |
|
LABORATORY REPORTS
|
|
|---|---|
| Document # | Document Title |
| VALIDATION OF DOUBLE POUCH MICROBIAL EFFICACY IN V-PRO AND STERRAD STERILIZERS | |
| VALIDATION OF DOUBLE POUCH MICROBIAL EFFICACY IN V-PRO AND STERRAD STERILIZERS | |
|
WALL CHARTS
|
|
|---|---|
| Document # | Document Title |
| PACK MONITORING WALL CHART | |
| V-PRO S2 CYCLE WEIGHT GUIDE | |
| V-PRO S2 CYCLE WEIGHT GUIDE | |
| V-PRO S2 CYCLE WEIGHT GUIDE | |
| INTERPRETATION GUIDE FOR CELERITY HP INDICATOR TAPE | |
| GUIDELINES FOR PREPARATION, PACKING AND LOADING OF AMSCO V-PRO LOW TEMPERATURE STERILIZATION SYSTEMS (ENGLISH) | |
| GUIDELINES FOR PREPARATION, PACKING AND LOADING OF AMSCO V-PRO LOW TEMPERATURE STERILIZATION SYSTEMS (FRENCH) | |
|
SELL SHEET
|
|
|---|---|
| Document # | Document Title |
| INFOGRAPHIC- V-PRO BEATS STERRAD WITH A 1-2 PUNCH | |
|
SAMPLE PROCEDURES
|
|
|---|---|
| Document # | Document Title |
| QUALIFICATION TESTING OF V-PRO STERILIZERS FOLLOWING INSTALLATION OR MAJOR REPAIR | |
|
BROCHURE
|
|
|---|---|
| Document # | Document Title |
| V-PRO S2 BROCHURE (ENGLISH) | |
| V-PRO S2 BROCHURE (CANADA) | |
| V-PRO S2 BROCHURE (FRENCH) | |
Lumen†
Non Lumen
Flexible†
Fast†
60 Minutes
28 Minutes
38 Minutes
19 Minutes