The V-PRO s2 Low Temperature Sterilizer delivers the right cycles to meet your SPD’s demands, while fitting in the tightest spaces of your department at just 22 ½" wide. This small low temperature sterilizer also offers a 19-minute cycle for quick turnaround of devices.
How the V-PRO s2 Low Temperature Sterilization System Works
The V-PRO s2 Low Temperature Sterilization System is a vaporized hydrogen peroxide (VHP) sterilizer that uses VAPROX® HC Sterilant and provides terminal sterilization of properly prepared (cleaned, rinsed and dried) medical devices. This compact sterilizer offers pre-programmed Cycles (Lumen Cycle, Non Lumen Cycle, Fast Cycle and Flexible Cycle) that operate at low temperature, processing medical devices without leaving toxic residues.
Please refer to the Operator Manual for detailed lumen dimension information and how to identify devices for loads.
Why Choose the V-PRO s2 Low Temperature Sterilization System?
Electronic Record Management with ConnectAssure™ Technology
Seamlessly connect and get immediate results from your V-PRO s2 Low Temperature Sterilizer, and Celerity HP BI Incubator with ConnectAssure Technology. Whether data is sent to your facility's tracking system or the ConnectAssure application, your cycle information including BI results are available with the click of a mouse for essential compliance reporting.
Sterilizer Dimensions, Chamber Size and Utility Requirements
Overall Sterilizer Dimensions are 22 ½" Wide x 32 ⅞" Deep x 61 ½" Tall. Chamber Size is 13" x 28" x 10" with 2.1 cubic feet of volume. V-PRO Sterilization systems require no plumbing, special ventilation or air supply, only a dedicated electrical connection is needed.
Device Compatibility Matrix
Confirm that your medical devices and accessories are compatible for processing with our
Low Temperature Systems.
Commonly Searched Devices Validated for Use in V-PRO Sterilizers
Olympus® | |
Device Type | Model |
Bronchoscopes | BF, such as BF1T60 |
Cystoscopes | CYF, such as CYF V2 |
Pleuroscope | LTF, such as LTF VH1 |
Karl Storz® | |
Device Type | Model |
Ureteroscope | 11278au1 |
Rhino Pharyngoscope | 11101RP2 |
C-Mac Intubation Fiberscope | 11302BD2 |
Fiberscope |
Stryker® | |
Device Type | Model |
HD Cameras |
1488-010-000 |
Medline® | |
Device Type | Model |
Sterilization Wraps | Various |
Cardinal Health™ | |
Device Type | Model |
Sterilization Wraps | Various |
Halyard Health® | |
Device Type | Model |
Sterilization Wraps | Various |
Do you have a device from the following manufacturers? Visit the V-PRO Device Matrix to find out if your device can be reprocessed in a V-PRO Low Temperature Sterilization System.
What can the V-PRO s2 Low Temperature Sterilizer sterilize?
Non-lumened instruments including non-lumened general medical instruments, non-lumened rigid, semi-rigid and flexible endoscopes. Confirm that your medical devices and accessories are compatible for processing with our Low Temperature Systems.
What is the V-PRO s2 Sterilizer’s fastest cycle?
The exclusive Fast Cycle can sterilize up to 4 lbs. of non-lumened instruments and single, double, and triple channel stainless steel lumens.
What does the V-PRO s2 Low Temperature Sterilization System consist of?
The V-PRO s2 Low Temperature Sterilization System consists of several components. These components include:
What is the difference between STERIS’s V-PRO Low Temperature Sterilization Systems?
Explore the differences between V-PRO Sterilizers and other common VHP Sterilizers based on important factors like chamber size, cycle time, utilities, electronic record keeping capabilities, and more using our interactive tool.
Celerity™ 20 HP Biological Indicator
Celerity™ HP Chemical Indicator
SPM® Surgical Asset Tracking Software
View, download and print technical information for V-PRO s2 including CAD Blocks, Revit Family Objects, equipment drawings, technical data sheets, and more on the STERIS Architect Portal.
ACCESS DESIGN RESOURCES
OPERATORS MANUAL
|
|
---|---|
Document # | Document Title |
V-PRO S2 | |
V-PRO S2 LOW TEMPERATURE STERILIZATION SYSTEM | |
V-PRO S2 LOW TEMPERATURE STERILIZATION SYSTEM | |
V-PRO S2 LOW TEMPERATURE STERILIZATION SYSTEM | |
V-PRO S2 LOW TEMPERATURE STERILIZATION SYSTEM | |
V-PRO S2 LOW TEMPERATURE STERILIZATION SYSTEM | |
V-PRO S2 LOW TEMPERATURE STERILIZATION SYSTEM | |
V-PRO S2 LOW TEMPERATURE STERILIZATION SYSTEM | |
V-PRO S2 LOW TEMPERATURE STERILIZATION SYSTEM | |
V-PRO S2 LOW TEMPERATURE STERILIZATION SYSTEM | |
V-PRO S2 LOW TEMPERATURE STERILIZATION SYSTEM - OPERATOR MANUAL (JA) |
TECH DATA SHEET
|
|
---|---|
Document # | Document Title |
V-PRO S2 LOW TEMPERATURE STERILIZATION SYSTEM |
TECHNICAL MONOGRAPH
|
|
---|---|
Document # | Document Title |
V-PRO S2 LOW TEMPERATURE STERILIZATION SYSTEM | |
MONOGRAPHIE DES DONNÉES TECHNIQUES - SYSTÈME DE STÉRILISATION À BASSE TEMPÉRATURE V-PRO S2 |
WALL CHARTS
|
|
---|---|
Document # | Document Title |
PACK MONITORING WALL CHART | |
V-PRO S2 CYCLE WEIGHT GUIDE |
SELL SHEET
|
|
---|---|
Document # | Document Title |
INFOGRAPHIC- V-PRO BEATS STERRAD WITH A 1-2 PUNCH | |
V-PRO TRAYS SELL SHEET |
BROCHURE
|
|
---|---|
Document # | Document Title |
V-PRO FAMILY BROCHURE | |
V-PRO S2 BROCHURE | |
V-PRO S2 BROCHURE | |
V-PRO S2 BROCHURE |
SAMPLE PROCEDURES
|
|
---|---|
Document # | Document Title |
ROUTINE MONITORING OF V-PRO STERILIZERS WITH CELERITY 20 HP BIOLOGICAL INDICATORS SAMPLE PROCEDURES | |
QUALIFICATION TESTING OF V-PRO STERILIZERS FOLLOWING INSTALLATION OR MAJOR REPAIR |
Device Compatibility Matrix
Confirm that your medical devices and accessories are compatible for processing with our Low Temperature Systems.