AMSCO 400 Series® Medium Steam Sterilizer

  • Processes up to fifteen, 25lb trays per cycle in the 60" unit
  • Designed to fit within previous sterilizer model’s footprint

REQUEST A QUOTE

The AMSCO 400 Series® Medium Steam Sterilizer is designed for today's demanding Sterile Processing Departments (SPDs). This autoclave safely sterilizes up to 375lbs per cycle, allowing you to efficiently handle high-volume sterilization and heavier trays while meeting compliance guidelines.

How Does the AMSCO 400 Medium Steam Sterilizer Work?

These prevacuum steam sterilizers efficiently sterilize heat- and moisture-stable materials and are equipped with prevacuum, gravity, liquid and all applicable test cycles. The autoclave minimizes condensation with a fully jacketed chamber and lessens the chance of air entering the chamber through the industry’s only non-lubricated, steam activated gasket with a 2-year warranty. Optimize your workflow and process up to fifteen, 25lb trays per cycle in the 60" unit.

Why Choose the AMSCO 400 Medium Steam Sterilizer?

The 26" x 37.5" chamber sizes are designed for efficient high-volume steam sterilization, and models are available in 36", 48" or 60" chamber lengths, with either single or double door configuration to optimize your workflow.

Electronic Record Management with ConnectAssure™ Technology

Seamlessly connect and get immediate results from your AMSCO 400 Medium Steam Sterilizer and Celerity™ STEAM Incubator with ConnectAssure Technology. Whether data is sent to your facility's tracking system or the ConnectAssure application, your cycle information including biological indicator (BI) results are available with the click of a mouse for essential compliance reporting.

Sterilizer Dimensions and Chamber Sizes

All autoclave models can be recessed in the wall or fully enclosed in a cabinet. AMSCO 400 Medium Steam Sterilizers are available with manual hinged or horizontal-sliding, automated door operation which is controlled by touch-screen. The AMSCO 400 Medium is designed to fit within previous sterilizer model’s footprint. Contact Us to discuss specifics about your project.

AMSCO® 400 SERIES MEDIUM STERILIZER WITH MANUAL HINGED DOOR

AMSCO® 400 SERIES MEDIUM STERILIZER WITH AUTOMATED HORIZONTAL SLIDING DOOR

AMSCO 400 Series Medium Sterilizer with Manual hinged door AMSCO 400 Series Medium Sterilizer with Automated Horizontal Sliding Door

Interior Chamber Dimensions, available in three chamber lengths:

  • 26 x 37.5 x 36" (660 x 950 x 910 mm) – 570.56 liters
  • 26 x 37.5 x 48" (660 x 950 x 1220 mm) – 764.94 liters
  • 26 x 37.5 x 60" (660 x 950 x 1520 mm) – 953.04 liters

Steam Sterilizer Utility Requirements

For complete autoclave utility requirements please see the Tech Data sheet on the Literature Tab. Hospitals can choose to either use building-supplied steam or utilize an independent steam generator.

Biological Indicators and Challenge Packs

VERIFY® Assert™ Self-Contained Biological Indicator

Provides final read within 40 minutes of incubation

VERIFY® Assert™ STEAM Process Challenge Device

For routine monitoring, qualification, and load monitoring of dynamic air removal cycles (LCB032/LCB033) and gravity cycles (LCB043)


Reusable Test Packs

VERIFY® All-In-One STEAM Reusable Test Pack

Designed to challenge vacuum assisted steam sterilizers operating at 270°F for a 4-minute exposure

Air Removal Tests

VERIFY® Bowie-Dick Test Pack

Unique failure patterns of the test can point out potential issues, helping to get your sterilizer up and running quickly
Dart® Daily Air Removal Test

Best-in-class and sensitive Air Removal test (Bowie Dick Test) to detect residual air

Chemical Indicators and Challenge Packs

VERIFY® STEAM Integrating Indicator

Seamlessly incorporates three critical variables of steam sterilization: steam, time, and temperature
VERIFY® STEAM Integrating Indicator 5CM

Reduces risk of releasing a non-sterile load before the corresponding biological indicator result is known

Chemical Indicator Tape

VERIFY® Steam and EO Tapes

Verify steam and ethylene oxide (EO) tapes adhere to both natural and synthetic materials commonly used in sterile processing.
Part number is required

By choosing genuine STERIS OEM replacement parts, you can be assured that each and every part is chosen based on the highest quality standards to ensure your equipment functions at its best. STERIS's OEM replacement parts promote compliance with regulatory requirements and organizational standards on equipment maintenance and repair.

Sterility Assurance and Monitoring

VERIFY® Assert™ Self-Contained
Biological Indicator

  • Provides final read within 40 minutes of incubation
  • For routine monitoring, qualification and load monitoring

VERIFY® STEAM Integrating Indicator

  • Incorporates three critical variables of steam sterilization – steam, time and temperature
  • Reduces risk of releasing a non-sterile load before the corresponding BI result is known

VERIFY® Bowie-Dick Test Pack

  • Consists of a series of air removal and steam penetration barriers
  • Advanced technology in thermochromic ink formulation can aid in the detection of steam quality issues

Printer Paper and Ink

Printer Paper Rolls

  • Box of 3 printer
    paper rolls

Printer Ribbon

  • Box of 2 
    cartridges

Other Steam Sterilizers

AMSCO® C Series Certified Pre-Owned Small Steam Sterilizer

  • Certified, Preowned
  • Available in Prevacuum or SFPP configuration

AMSCO® 400 Small Steam Sterilizer

  • Validated for 25 lb. sets
  • Accommodates larger bariatric and orthopedic devices

AMSCO® Evolution® Medium Steam Sterilizer

  • Processes up to 500 lbs of instruments
  • Elliptical chamber accommodates today's larger instrument containers
  • STERI-GREEN PLUS® reduces water consumption to 1 gal/cycle
  • Available with space saving integral steam generation

AMSCO® Evolution® Floor Loader Steam Sterilizer

  • Processes up to 625 lbs of instruments
  • Fully jacketed chamber minimizes condensation

Sterile Processing Department Equipment

Sterile Processing Department Accessories

  • Prep and pack tables
  • Steam sterilizer loading equipment
  • Stainless steel transportation carts

Washing and Decontamination Systems

  • Washer/disinfectors
  • Ultrasonic cleaners
  • Hospital cart washers
  • Decontamination sinks

V-PRO® Low Temperature Sterilization Systems

  • For terminal sterilization of heat- and moisture-sensitive devices
  • Plasma-free process allows maximum use of chamber volume

SYSTEM 1E® Liquid Chemical Sterilant Processing System

  • For safe and effective reprocessing of heat-sensitive critical and semi-critical devices
  • Rapid 23-minute cycle
BROCHURE
Document # Document Title
HOW TO: MEETING YOUR SUSTAINABILITY GOALS WITH STERIS EQUIPMENT
AMSCO 400 SERIES MEDIUM STEAM STERILIZER BROCHURE-PERFORMANCE MEETS COMPLICANCE (FORMERLY CHIMERON)
AMSCO STEAM STERILIZER FAMILY BROCHURE
CAPITAL EQUIPMENT SOLUTIONS FOR ASC AND SMALL FACILITIES
AMBULATORY SURGERY CENTER SOLUTIONS BROCHURE
A LINE OF ONE BROCHURE
AMSCO 400 SERIES MEDIUM STEAM STERILIZER BROCHURE (.PDF ONLY)
SELL SHEET
Document # Document Title
SECURECARE TRAINING COURSE DESCRIPTION SELL SHEET - AMSCO CENTURY MEDIUM STEAM STERILIZER
SECURECARE ON-SITE TRAINING REDESIGN - AMSCO 400 MEDIUM
ECURECARE TRAINING CLASS AMSCO 400 SERIES MEDIUM STEAM STERILIZER
SECURECARE ON-SITE TRAINING REDESIGN - AMSCO 400 MEDIUM
SECURECARE LOADING CAR AND TRANSFER CARRIAGE MAINTENANCE CONTRACTS FOR CANADA ONLY
SECURECARE LOADING CAR AND TRANSFER CARRIAGE MAINTENANCE CONTRACTS
SECURECARE LOADING CAR AND TRANSFER CARRIAGE MAINTENANCE CONTRACTS SELL SHEET - FRENCH CANADIAN
SECURECARE STEAM FILTER AND STEAM SEPARATOR SERVICE PLANS
SECURECARE AMSCO 400 TRANSFER CARRIAGE MAINTENANCE KIT SELL SHEET - FC
SECURECARE DIAGNOSTIC SOLUTIONS SELL SHEET
QUICK TROUBLESHOOTING GUIDE ¿ STEAM STERILIZERS
SECURECARE LOADING CAR AND TRANSFER CARRIAGE MAINTENANCE KIT - CANADA ONLY
SECURECARE STERILIZER CHAMBER CLEANING SELL SHEET
SECURECARE STEAM FILTER AND STEAM SEPARATOR SERVICE PLAN
DIAGNOSTIC SOLUTIONS SELL SHEET
SECURECARE AMSCO 400 TRANSFER CARRIAGE MAINTENANCE KIT SELL SHEET
TECHNICAL BULLETINS
Document # Document Title
STERIS STEAM STERILIZATION CLEANING PROCEDURE
TECHNICAL TIPS
Document # Document Title
GUIDE TO STEAM STERILIZATION CYCLES - STEAM FLUSH PRESSURE PULSE
UNDERSTANDING THE COMPLEMENTARY ROLES OF AIR REMOVAL (BOWIE-DICK), LEAK AND BIOLOGICAL TESTING IN STEAM STERILIZATION
GUIDE TO OPTIMAL STEAM GENERATION
GUIDE TO STAINLESS STEEL CORROSION REMOVAL
WALL CHARTS
Document # Document Title
ROUTINE CHECKLIST FOR ALL AMSCO SMALL, MEDIUM AND FLOORLOADER STEAM STERILIZERS
Live Chat

Enter Your Zip Code to Locate Your Sales Representative

Zip Code is required.