Delivering unparalleled productivity for day-to-day Operating Room needs, the V-PRO maX 2 Low Temperature Sterilization System is designed for use in the terminal sterilization of medical devices. STERIS’s V-PRO maX 2 Sterilizer features the Fast Non Lumen cycle, allowing you to sterilize devices like cameras, telescopes, batteries, and laryngoscope blades in just 16 minutes.
How V-PRO maX 2 Low Temperature Sterilization System Works
This Low Temperature Sterilization System using proprietary Sterilant is intended for use in the terminal Sterilization of properly prepared (cleaned, rinsed, and dried, refer to Cleaning, Rinsing, and Drying in the Operator's Manual) medical devices in Healthcare Facilities. The preprogrammed Sterilization Cycles operate at low pressure and temperature, suitable for processing medical devices without leaving toxic residues.
The V-PRO maX 2 Sterilizer offers five cycles to efficiently sterilize the widest range of surgical instruments and medical devices using our proprietary vaporized hydrogen peroxide technology:
Cycle | Lumen† | Non Lumen | Flexible† | Fast Non Lumen | 3D Specialty Cycles |
---|---|---|---|---|---|
†Refer the operator manual for lumen size limitations. *da Vinci is a registered trademark of Intuitive Surgical, Inc. |
|||||
Cycle Time | 52 Minutes | 28 Minutes | 35 Minutes | 16 Minutes | Varies |
Load Weight | 19.65 lb/8.9 kg | 50 lb/22.7 kg | 2 Scopes | 24 lb/11 kg: 1 scope and Non Lumened and Short Lumened Devices |
11 lb/5 kg, Non Lumened Devices Peel Pouch Only |
For Cycle Details, Please Click Here |
Device Examples |
|
|
|
|
|
The innovative Moisture Check is included in every cycle to help confirm loads are dry and prevent cycle aborts. The Fast Non Lumen Cycle, only available with the V-PRO maX 2 Sterilizer, uses half the sterilant compared to all other V-PRO Sterilizer cycles.
Why V-PRO maX 2 Low Temperature Sterilization System?
Supporting Your Sustainability Goals
Olympus®
Device Type | Model |
---|---|
Bronchoscopes | BF, such as BF1T60 |
Cystoscopes | CYF, such as CYF V2 |
Pleuroscope | LTF, such as LTF VH1 |
Karl Storz®
Device Type | Model |
---|---|
Ureteroscope | 11278AU1 |
Rhino Pharyngoscope | 11101RP2 |
C-Mac Intubation Fiberscope | 11302BD2 |
Fiberscope |
Intuitive Surgical®
Device Type | Model |
---|---|
Endoscopes | For Xi and Si Robot |
Stryker
Device Type | Model |
HD Cameras |
1488-010-000 |
Cardinal Health™
Device Type | Model |
---|---|
Sterilization Wraps | Various |
Medline®
Device Type | Model |
---|---|
Sterilization Wraps | Various |
Halyard Health®
Device Type | Model |
---|---|
Sterilization Wraps | Various |
Visit the V-PRO Device Matrix to find out if your device can be reprocessed in a V-PRO Low Temperature Sterilization System. The Device Matrix contains information on devices from hundreds of manufacturers including:
Seamlessly connect and get immediate results from your V-PRO maX 2 Low Temperature Sterilizer and Celerity Incubator with ConnectAssure Technology. ConnectAssure Technology Data Export software helps promote compliance throughout the facility by interfacing compatible STERIS products with SPM Surgical Asset Tracking Software and many of the other leading instrument tracking systems.
What can the V-PRO maX 2 Low Temperature Sterilizer sterilize?
The V-PRO maX 2 Low Temperature Sterilizer can sterilize more than just instruments that are heat sensitive. Devices like batteries, rigid endoscopes, general stainless steel instruments, bronchoscopes, and others will benefit from short cycle times with a gentle, low temperature process.
How fast can the V-PRO maX 2 Low Temperature Sterilizer sterilize?
The V-PRO maX 2 Low Temperature Sterilizer has four cycles that range from very fast to extremely fast, with all cycles starting with a moisture checking condition phase included in the total time:
For the fastest turn-around, the Fast Non Lumen Cycle will process general stainless steel and non lumened instruments in pouches or pouched trays in around 16 minutes.
What STERIS accessories are designed to work with the V-PRO maX 2 Low Temperature Sterilizer?
What is the difference between STERIS’s V-PRO Low Temperature Sterilization Systems?
Explore the differences between V-PRO Sterilizers and other common VH2O2 Sterilizers based on important factors like chamber size, cycle time, utilities, electronic record-keeping capabilities, and more using our interactive tool.
OPERATORS MANUAL
|
|
---|---|
Document # | Document Title |
V-PRO MAX 2 LOW TEMPERATURE STERILIZATION SYSTEM | |
AMSCO V-PRO MAX 2 OPERATOR MANUAL - NORTH AMERICA | |
V-PRO MAX 2 LOW TEMPERATURE STERILIZATION SYSTEM (FOR USE OUTSIDE NORTH AMERICA) - OPERATOR MANUAL (SR) [NOT RWS] | |
V-PRO MAX 2 LOW TEMPERATURE STERILIZATION SYSTEM (FOR USE OUTSIDE NORTH AMERICA) - OPERATOR MANUAL (TR) [NOT RWS] | |
V-PRO MAX 2 LOW TEMPERATURE STERILIZATION SYSTEM (FOR USE OUTSIDE NORTH AMERICA) | |
V-PRO MAX 2 LOW TEMPERATURE STERILIZATION SYSTEM (FOR USE OUTSIDE NORTH AMERICA) | |
V-PRO MAX 2 LOW TEMPERATURE STERILIZATION SYSTEM (FOR USE OUTSIDE NORTH AMERICA) | |
V-PRO MAX 2 LOW TEMPERATURE STERILIZATION SYSTEM (FOR USE OUTSIDE NORTH AMERICA) | |
V-PRO MAX 2 LOW TEMPERATURE STERILIZATION SYSTEM (FOR USE OUTSIDE NORTH AMERICA) - OPERATOR MANUAL (RU) | |
V-PRO MAX 2 LOW TEMPERATURE STERILIZATION SYSTEM (FOR USE OUTSIDE NORTH AMERICA) - OPERATOR MANUAL (FI) | |
V-PRO MAX 2 LOW TEMPERATURE STERILIZATION SYSTEM (FOR USE OUTSIDE NORTH AMERICA) | |
V-PRO MAX 2 LOW TEMPERATURE STERILIZATION SYSTEM (FOR USE OUTSIDE NORTH AMERICA) - OPERATOR MANUAL (NL) | |
V-PRO MAX 2 LOW TEMPERATURE STERILIZATION SYSTEM (FOR USE OUTSIDE NORTH AMERICA) | |
V-PRO MAX 2 LOW TEMPERATURE STERILIZATION SYSTEM (FOR USE OUTSIDE NORTH AMERICA) - OPERATOR MANUAL (LT) | |
V-PRO MAX 2 LOW TEMPERATURE STERILIZATION SYSTEM (FOR USE OUTSIDE NORTH AMERICA) - OPERATOR MANUAL (SV) | |
V-PRO MAX 2 LOW TEMPERATURE STERILIZATION SYSTEM (FOR USE OUTSIDE NORTH AMERICA) - OPERATOR MANUAL (SK) | |
V-PRO MAX 2 LOW TEMPERATURE STERILIZATION SYSTEM (FOR USE OUTSIDE NORTH AMERICA) | |
V-PRO MAX 2 LOW TEMPERATURE STERILIZATION SYSTEM (FOR USE OUTSIDE NORTH AMERICA) - OPERATOR MANUAL (LV) | |
V-PRO MAX 2 LOW TEMPERATURE STERILIZATION SYSTEM (FOR USE OUTSIDE NORTH AMERICA) - OPERATOR MANUAL (CZ) | |
AMSCO V-PRO MAX 2 (EU) (FR) | |
AMSCO V-PRO MAX 2 OPERATOR MANUAL - CHINA-ONLY (ZH-CN) | |
AMSCO V-PRO MAX 2 OPERATOR MANUAL - CHINA-ONLY (ZH-CN) | |
AMSCO V-PRO MAX 2 OPERATOR MANUAL - CHINA-ONLY (ZH-CN) |
TECH DATA SHEET
|
|
---|---|
Document # | Document Title |
V-PRO MAX 2 | |
V-PRO MAX 2 LOW TEMPERATURE STERILIZATION UNIT | |
V-PRO MAX 2 LOW TEMPERATURE STERILIZATION UNIT | |
V-PRO MAX 2 LOW TEMPERATURE STERILIZATION UNIT | |
V-PRO MAX 2 LOW TEMPERATURE STERILIZATION UNIT | |
V-PRO MAX 2 LOW TEMPERATURE STERILIZATION UNIT | |
V-PRO MAX 2 LOW TEMPERATURE STERILIZATION UNIT | |
V-PRO MAX 2 LOW TEMPERATURE STERILIZATION UNIT | |
V-PRO MAX 2 LOW TEMPERATURE STERILIZATION UNIT | |
V-PRO MAX 2 LOW TEMPERATURE STERILIZATION UNIT | |
VAPROX HC STERILANT PB011/012 | |
V-PRO MAX 2 LOW TEMPERATURE STERILIZATION SYSTEM (AUSTRALIA) |
TECHNICAL MONOGRAPH
|
|
---|---|
Document # | Document Title |
TECHNICAL DATA MONOGRAPH - V-PRO MAX 2 LOW TEMPERATURE STERILIZATION SYSTEM | |
TECHNICAL DATA MONOGRAPH - V-PRO MAX 2 LOW TEMPERATURE STERILIZATION SYSTEM | |
TECHNICAL DATA MONOGRAPH - V-PRO MAX 2 LOW TEMPERATURE STERILIZATION SYSTEM (SPANISH) | |
TECHNICAL DATA MONOGRAPH - V-PRO MAX 2 LOW TEMPERATURE STERILIZATION SYSTEM (ITALIAN) | |
TECHNICAL DATA MONOGRAPH - V-PRO MAX 2 LOW TEMPERATURE STERILIZATION SYSTEM (PORTUGUESE) | |
TECHNICAL DATA MONOGRAPH - V-PRO MAX 2 LOW TEMPERATURE STERILIZATION SYSTEM (GERMAN) |
LABORATORY REPORTS
|
|
---|---|
Document # | Document Title |
VALIDATION OF DOUBLE POUCH MICROBIAL EFFICACY IN V-PRO AND STERRAD STERILIZERS | |
VALIDATION OF DOUBLE POUCH MICROBIAL EFFICACY IN V-PRO AND STERRAD STERILIZERS |
WALL CHARTS
|
|
---|---|
Document # | Document Title |
PACK MONITORING WALL CHART | |
V-PRO MAX2 CYCLE WEIGHT GUIDE | |
V-PRO MAX 2 3D MATERIALS WALL CHART | |
OPERATING AND INTERPRETING RESULTS FOR V-PRO MAX AND V-PRO MAX 2 STERILIZERS | |
OPERATING AND INTERPRETING RESULTS FOR V-PRO MAX AND V-PRO MAX 2 STERILIZERS (FRENCH) | |
MAX 2 AND 100NX QUICK REFERENCE GUIDE | |
MAX 2 AND 100NX QUICK REFERENCE GUIDE (CANADA) | |
MAX 2 AND 100NX QUICK REFERENCE GUIDE (FRENCH) | |
V-PRO MAX AND MAX 2 ROUTINE CHECKLIST FOR STERILIZER MAINTENANCE |
SELL SHEET
|
|
---|---|
Document # | Document Title |
INFOGRAPHIC- V-PRO BEATS STERRAD WITH A 1-2 PUNCH |
BROCHURE
|
|
---|---|
Document # | Document Title |
V-PRO MAX 2 3D BROCHURE | |
V-PRO MAX 2 BROCHURE (ENGLISH) | |
V-PRO MAX 2 BROCHURE (FRANCE) |
SAMPLE PROCEDURES
|
|
---|---|
Document # | Document Title |
QUALIFICATION TESTING OF V-PRO STERILIZERS FOLLOWING INSTALLATION OR MAJOR REPAIR |