Delivering unparalleled productivity for day-to-day Operating Room needs, the V-PRO maX 2 Low Temperature Sterilization System is designed for use in terminal sterilization of medical devices. STERIS’s V-PRO maX 2 Sterilizer features the new Fast Non Lumen Cycle allowing you to sterilize devices like cameras, telescopes, batteries and laryngoscope blades in just 16 minutes.
How V-PRO maX 2 Low Temperature Sterilization System Works
The V-PRO maX 2 Sterilizer is a hydrogen peroxide sterilizer that provides four cycles to efficiently sterilize the widest range of instruments and devices, using our proprietary vaporized hydrogen peroxide technology:
The innovative Moisture Check is included in every cycle to help confirm loads are dry and prevent cycle aborts. The Fast Non Lumen Cycle, only available with the V-PRO maX 2 Sterilizer, uses half the sterilant compared to all other V-PRO Sterilizer cycles.
Why V-PRO maX 2 Low Temperature Sterilization System?
Electronic Record Management with ConnectAssure™ Technology
Seamlessly connect and get immediate results from your V-PRO maX 2 Low Temperature Sterilizer, and Celerity HP BI Incubator with ConnectAssure Technology. Whether data is sent to your facility's tracking system or the ConnectAssure application, your cycle information including BI results are available with the click of a mouse for essential compliance reporting.
Device Compatibility Matrix
Confirm that your medical devices and accessories are compatible for processing with our Low Temperature Systems.
Commonly Searched Devices Validated for Use in V-PRO Sterilizers
Olympus® | |
Device Type | Model |
Bronchoscopes | BF, such as BF1T60 |
Cystoscopes | CYF, such as CYF V2 |
Pleuroscope | LTF, such as LTF VH1 |
Karl Storz® | |
Device Type | Model |
Ureteroscope | 11278au1 |
Rhino Pharyngoscope | 11101RP2 |
C-Mac Intubation Fiberscope | 11302BD2 |
Fiberscope |
Intuitive Surgical® | |
Device Type | Model |
Endoscopes | For Xi and Si Robot |
Stryker® | |
Device Type | Model |
HD Cameras |
1488-010-000 |
Cardinal Health™ | |
Device Type | Model |
Sterilization Wraps | Various |
Medline® | |
Device Type | Model |
Sterilization Wraps | Various |
Halyard Health® | |
Device Type | Model |
Sterilization Wraps | Various |
Do you have a device from the following manufacturers? Visit the V-PRO Device Matrix to find out if your device can be reprocessed in a V-PRO Low Temperature Sterilization System.
What can the V-PRO maX 2 Low Temperature Sterilizer sterilize?
Each Cycle can sterilize non-lumened instruments with diffusion-restricted spaces such as the hinged portion of forceps and scissors. Only stainless steel or titanium diffusion-restricted spaces should be processed in the Non Lumen Cycle and Fast Non Lumen Cycle.
What is the V-PRO maX 2 Sterilizer’s fastest cycle?
The Fast Non Lumen Cycle allows you to process up to 11 lbs. (5 kg.) of non lumen devices in just 16 minutes.
What does the V-PRO maX 2 Low Temperature Sterilization System consist of?
What is the difference between STERIS’s V-PRO Low Temperature Sterilization Systems?
Explore the differences between V-PRO Sterilizers and other common VHP Sterilizers based on important factors like chamber size, cycle time, utilities, electronic record keeping capabilities, and more using our interactive tool.
Celerity™ 20 HP Biological Indicator
Celerity™ HP Chemical Indicator
SPM® Surgical Asset Tracking Software
View, download and print technical information for V-PRO maX 2 including CAD Blocks, Revit Family Objects, equipment drawings, technical data sheets, and more on the STERIS Architect Portal.
ACCESS DESIGN RESOURCES
OPERATORS MANUAL
|
|
---|---|
Document # | Document Title |
V-PRO MAX 2 LOW TEMPERATURE STERILIZATION SYSTEM (FOR USE OUTSIDE NORTH AMERICA) | |
V-PRO MAX 2 LOW TEMPERATURE STERILIZATION SYSTEM (FOR USE OUTSIDE NORTH AMERICA) - OPERATOR MANUAL (SR) [NOT RWS] | |
V-PRO MAX 2 LOW TEMPERATURE STERILIZATION SYSTEM (FOR USE OUTSIDE NORTH AMERICA) - OPERATOR MANUAL (TR) [NOT RWS] | |
V-PRO MAX 2 LOW TEMPERATURE STERILIZATION SYSTEM (FOR USE OUTSIDE NORTH AMERICA) | |
V-PRO MAX 2 LOW TEMPERATURE STERILIZATION SYSTEM (FOR USE OUTSIDE NORTH AMERICA) | |
V-PRO MAX 2 LOW TEMPERATURE STERILIZATION SYSTEM (FOR USE OUTSIDE NORTH AMERICA) | |
V-PRO MAX 2 LOW TEMPERATURE STERILIZATION SYSTEM (FOR USE OUTSIDE NORTH AMERICA) | |
V-PRO MAX 2 LOW TEMPERATURE STERILIZATION SYSTEM (FOR USE OUTSIDE NORTH AMERICA) - OPERATOR MANUAL (RU) | |
V-PRO MAX 2 LOW TEMPERATURE STERILIZATION SYSTEM (FOR USE OUTSIDE NORTH AMERICA) - OPERATOR MANUAL (FI) | |
V-PRO MAX 2 LOW TEMPERATURE STERILIZATION SYSTEM (FOR USE OUTSIDE NORTH AMERICA) | |
V-PRO MAX 2 LOW TEMPERATURE STERILIZATION SYSTEM (FOR USE OUTSIDE NORTH AMERICA) - OPERATOR MANUAL (NL) | |
V-PRO MAX 2 LOW TEMPERATURE STERILIZATION SYSTEM (FOR USE OUTSIDE NORTH AMERICA) | |
V-PRO MAX 2 LOW TEMPERATURE STERILIZATION SYSTEM (FOR USE OUTSIDE NORTH AMERICA) - OPERATOR MANUAL (LT) | |
V-PRO MAX 2 LOW TEMPERATURE STERILIZATION SYSTEM (FOR USE OUTSIDE NORTH AMERICA) - OPERATOR MANUAL (SV) | |
V-PRO MAX 2 LOW TEMPERATURE STERILIZATION SYSTEM (FOR USE OUTSIDE NORTH AMERICA) - OPERATOR MANUAL (SK) | |
V-PRO MAX 2 LOW TEMPERATURE STERILIZATION SYSTEM (FOR USE OUTSIDE NORTH AMERICA) | |
V-PRO MAX 2 LOW TEMPERATURE STERILIZATION SYSTEM (FOR USE OUTSIDE NORTH AMERICA) - OPERATOR MANUAL (LV) | |
V-PRO MAX 2 LOW TEMPERATURE STERILIZATION SYSTEM (FOR USE OUTSIDE NORTH AMERICA) - OPERATOR MANUAL (CZ) |
TECH DATA SHEET
|
|
---|---|
Document # | Document Title |
V-PRO MAX 2 LOW TEMPERATURE STERILIZATION UNIT | |
V-PRO MAX 2 LOW TEMPERATURE STERILIZATION UNIT | |
V-PRO MAX 2 LOW TEMPERATURE STERILIZATION UNIT | |
V-PRO MAX 2 LOW TEMPERATURE STERILIZATION UNIT | |
V-PRO MAX 2 LOW TEMPERATURE STERILIZATION UNIT | |
V-PRO MAX 2 LOW TEMPERATURE STERILIZATION UNIT | |
V-PRO MAX 2 LOW TEMPERATURE STERILIZATION UNIT | |
V-PRO MAX 2 LOW TEMPERATURE STERILIZATION UNIT | |
V-PRO MAX 2 LOW TEMPERATURE STERILIZATION UNIT |
TECHNICAL MONOGRAPH
|
|
---|---|
Document # | Document Title |
TECHNICAL DATA MONOGRAPH - V-PRO MAX 2 LOW TEMPERATURE STERILIZATION SYSTEM |
WALL CHARTS
|
|
---|---|
Document # | Document Title |
PACK MONITORING WALL CHART | |
OPERATING AND INTERPRETING RESULTS FOR V-PRO MAX AND V-PRO MAX 2 STERILIZERS |
BROCHURE
|
|
---|---|
Document # | Document Title |
V-PRO CONSUMABLES BROCHURE | |
V-PRO FAMILY BROCHURE | |
V-PRO MAX 2 BROCHURE | |
V-PRO MAX 2 BROCHURE |
SELL SHEET
|
|
---|---|
Document # | Document Title |
INFOGRAPHIC- V-PRO BEATS STERRAD WITH A 1-2 PUNCH | |
V-PRO COMPARISON MATRIX - MAX 2, 60, STERRAD 100NX AND STERRAD NX | |
V-PRO COMPARISON MATRIX - MAX 2, 60, STERRAD 100NX, STERRAD 100S AND STERRAD NX | |
V-PRO COMPARISON MATRIX - MAX 2 AND STERIZONE VP4 | |
V-PRO COMPARISON MATRIX - MAX 2, 60, STERRAD 100NX AND STERIZONE VP4 | |
V-PRO TRAYS SELL SHEET | |
V-PRO COMPARISON MATRIX - MAX 2 AND 100NX |
SAMPLE PROCEDURES
|
|
---|---|
Document # | Document Title |
ROUTINE MONITORING OF V-PRO STERILIZERS WITH CELERITY 20 HP BIOLOGICAL INDICATORS SAMPLE PROCEDURES | |
QUALIFICATION TESTING OF V-PRO STERILIZERS FOLLOWING INSTALLATION OR MAJOR REPAIR |
Device Compatibility Matrix
Confirm that your medical devices and accessories are compatible for processing with our Low Temperature Systems.