Product Overview
The STERIS Certified Pre-Owned AMSCO 400 Small Sterilizer (autoclave) is designed to meet the demanding needs of Sterile Processing Departments (SPDs). This small-sized autoclave can safely sterilize up to 250 lbs. per cycle, efficiently managing sterilization processes while adhering to compliance standards.
- Available in two chamber lengths: 16" or 20" chamber
- Installation options: Recessed in the wall or free-standing with cabinet
- Accessibility: Safe access to all components from the front and left side of the sterilizer
- Remote monitoring: Real-time remote monitoring of sterilizer function and cycle parameters with ConnectCare℠
- Maintenance and service: Preventive maintenance and comprehensive service agreements
The STERIS Certified Pre-Owned (CPO) AMSCO 400 Small Sterilizer undergoes a precise STERIS certification process. STERIS CPO technicians thoroughly inspect and refurbish each unit to ensure it meets STERIS specifications to be like-new aesthetically and operationally.
Specifications
The STERIS Certified Pre-Owned AMSCO 400 Small Steam Sterilizers are equipped with a single door and open or receded mounting for optimal workflow.
Sterilizer Dimensions and Chamber Sizes
| Model | Interior Chamber Dimensions | Max. Outside Dimensions |
|---|---|---|
|
*May vary slightly by specific model configuration. |
||
| 16x16 Models |
16”L x 16”W x 26"H (406 x 406 x 660mm) 108.79 liters |
36 7/8”L* x 26”W x 74 ½H” (937* x 660 x 1891mm) |
| 20x20 Models |
20”L x 20”W x 38H" (508 x 508 x 965 mm) 249.03 liters |
45 5/8”L* x 30”W x 74 ½H” (1159* x 762 x 1891mm) |
- Re-Insulate Chamber
- Replace steam manifold
- Replace heat exchanger Assy
- Replace jacket trap
- Replace pressure regulator
- Replace exhaust manifold
- Replace the check valve
- Temperature and pressure calibration
- Verify door operation
- Check relays and contactors for arc damage
- Replace conductivity/ float probes
- Re-finish all stainless-steel panels or replace them if needed
- Replace vacuum pump
- Replace water inlet
- Replace the safety valve
- Replace jacket trap check valve
- Replace the feed water valve
- Check chamber level sensor
- Check appearance for leaks and damage
- Replace chamber strainer
- Replace steam baffle