STERIS Corporation - Helping to provide a healthier today and a safer tomorrow.

VERIFY® Biological Steam Test Pack

VERIFY Biological Steam Test Packs are used to monitor and qualify dynamic air removal (prevacuum and steam-flush pressure-pulse) steam sterilization (autoclave) cycles performed at 270°F/132°C and gravity cycles performed at 250°F/121°C.

REQUEST A QUOTE

 

Conventional Biological Indicator growth means that the VERIFY Biological Steam Test Pack can be used to qualify autoclaves.

VERIFY® Biological Steam Test Packs are used to monitor and qualify dynamic air removal (prevacuum and steam-flush pressure-pulse) steam sterilization (autoclave) cycles performed at 270°F/132°C and gravity cycles performed at 250°F/121°C. The VERIFY Biological Steam Test Pack provides the same challenge as the AAMI 16-towel biological indicator test pack. Each pack contains a chemical indicator and a VERIFY® Self-Contained Biological Indicator.

  • 24-hour final result
  • Chemical Indicator provides immediate identification of processed test packs
  • Equivalent to an ANSI/AAMI ST79 16-Towel Biological Indicator Test Pack
  • For routine monitoring and qualification
Product Number Description Quantity

S3065

VERIFY Biological Steam Test Pack

Box (20 packs and 5 controls)

S3069

VERIFY Biological Steam Test Pack

Box (20 packs and 20 controls)

An incubator and activator set are required for proper use of the VERIFY® Biological Steam Test Pack.

Product Number Description Quantity

S3075

VERIFY Vial Activator Set

Each

S3080

VERIFY 8 Well Dual Incubator (55-60°C and 35-39°C)

Each

S3082

VERIFY 28 Well Incubator for Steam (55-60°C)

Each

S3271

VERIFY 6 Well Steam Incubator (55-60°C)

Each

Other Sterility Assurance and Monitoring Products

Biological Indicators

  • For routine monitoring, product testing and qualification of steam, EO, and vaporized hydrogen peroxide sterilization processes

Chemical Indicators

  • Internal chemical indicator strips and challenge packs capture sterilization or disinfection failures through immediate results

Daily Air Removal Test/Bowie-Dick Test

  • Evaluate the performance of prevacuum sterilizers by confirming adequate air removal from the sterilizer chamber

Reusable Test Packs

  • Designed to challenge vacuum assisted steam sterilizers, these reusable test packs offer environmental and budgetary benefits

Record Keeping and Labeling

  • Envelopes, forms, record cards and labels to quickly document common sterilization, high level disinfection and cleaning processes
SELL SHEET
Document # Document Title
VERIFY BIOLOGICAL STEAM TEST PACKS
SAMPLE PROCEDURES
Document # Document Title
SAMPLE PROCEDURE: STEAM STERILIZATION LOAD MONITORING WITH THE VERIFY SIXCESS CHALLENGE PACKS AND THE VERIFY BIOLOGICAL STEAM BIOLOGICAL TEST PACK
Live Chat

Enter Your Zip Code to Locate Your Sales Representative

Zip Code is required.