VERIFY™ Biological/Integrator Challenge Pack
- Read Time: Provides results in 24 hours
- Cycles: Dynamic Air Removal Cycles at 270°F/132°C and Gravity Cycles at 250°F/121°C
- Feature: Type 5 chemical integrator meets ANSI/AAMI/ISO 11140-1 requirements
VERIFY Biological/Integrator Challenge Packs are used to monitor dynamic air removal (prevacuum and steam-flush pressure-pulse) steam sterilization cycles performed at 270°F/132°C or gravity cycles performed at 250°F/121°C.
How VERIFY Biological/Integrator Challenge Packs Work
The VERIFY Biological/Integrator Challenge Pack is a preassembled pack consisting of a clear plastic tube with a plastic vented closure at each end. Each challenge pack contains a VERIFY Self-Contained Biological Indicator (SCBI) and a Type 5 chemical integrator, and cotton-filled gauze sponges and foam discs to provide a challenge to the sterilization process.
Check out the new:
Celerity™ 20 STEAM Process Challenge DeviceCelerity 20 STEAM Process Challenge Device for fast 20 minute results.
The VERIFY Biological/Integrator Challenge Pack is placed toward the bottom front of the loaded autoclave chamber near the drain. After the cycle has completed, technicians should immediately remove the challenge pack from the sterilizer and allow cooling before interpreting the chemical indicators and incubating the biological indicator for 24-hours before final results are read. See the instructions sheet enclosed in each box for detailed use directions.
Why VERIFY Biological/Integrator Challenge Packs?
These biological integrator challenge packs provide routine monitoring of specific steam sterilization cycles, with a compact design. Additional benefits of the VERIFY Biological/Integrator Challenge Packs include:
- Type 5 chemical integrator meets ANSI/AAMI/ISO 11140-1 requirements
- Equivalent to an ANSI/AAMI ST79 16-Towel Biological Indicator Test Pack
SHOP NOW
Browse a complete Item Number list and easily reorder VERIFY® Biological/Integrator Challenge Pack products on Shop STERIS.
| Product Number | Description | |
|---|---|---|
| LCB006 | VERIFY BI/CI CHALLENGE PACK (20 PKS & 5 CNTRLS/BX) | |
| LCB007 | VERIFY BI/CI CHALLENGE PACK(20 PKS & 20 CNTRLS/BX) |
An incubator and activator set are required for proper use of the VERIFY Biological/Integrator Challenge Packs.
| Product Number | Description | Quantity | |
|---|---|---|---|
|
S3075 |
VERIFY™ Vial Activator Set |
Each |
|
|
S3080 |
VERIFY™ 28 Well Dual Incubator (55-60°C and 35-39°C) |
Each |
|
|
S3082 |
VERIFY™ 28 Well Incubator for Steam (55-60°C) |
Each |
|
|
S3271 |
VERIFY™ 6 Well Steam Incubator (55-60°C) |
Each |
|
TECH DATA SHEET
|
|
|---|---|
| Document # | Document Title |
| VERIFY DUAL TEMPERATURE 28-WELL INCUBATOR (220 VAC) FOR VERIFY SELF-CONTAINED BIOLOGICAL INDICATORS (S3081) | |
|
SAMPLE PROCEDURES
|
|
|---|---|
| Document # | Document Title |
| SAMPLE PROCEDURE: STEAM STERILIZATION LOAD MONITORING WITH VERIFY SIXCESS CHALLENGE PACKS AND VERIFY BIOLOGICAL/INTEGRATOR CHALLENGE PACK | |
|
MSDS
|
|
|---|---|
| Document # | Document Title |
| VERIFY SCBI AND TEST PACKS - ITALIAN | |
| VERIFY SCBI AND TEST PACKS - PORTUGUESE | |
| VERIFY SCBI AND TEST PACKS - UNITED KINGDOM | |
|
SDS
|
|
|---|---|
| Document # | Document Title |
| VERIFY BIOLOGICAL/INTEGRATOR CHALLENGE PACK | |