Certificates of Analysis
Device Compatibility Matrix
Instructions Fro Use
Medivators Hookup Guide
Safety Data Sheets
Contact Form
Get a Quote or Information
Healthcare Live Chat
Locate Your STERIS Representative
United States
Canada (EN)
Canada (FR)
United Kingdom
Europe, Middle East and Africa
Australia
Asia-Pacific
Brasil
México
América Latina
Revital-Ox® RESERT® High Level Disinfectant (HLD) is a high level disinfectant when used or reused undiluted for a maximum of 21 days at a minimum temperature of 20°C (68°F) for a minimum immersion time of 8 minutes. This high level disinfection solution is a ready-to-use option for devices for which alternative methods of terminal processing, including aldehyde [glutaraldehyde and ortho-phthalaldehyde (OPA)] solutions, are not suitable or available.
How Revital-Ox RESERT High Level Disinfectant Works
This hydrogen peroxide high level disinfectant is a ready-to-use liquid chemical germicide for use in both manual soaking and open architecture automated endoscope reprocessors. The product is a 2.0% nominal hydrogen peroxide solution with a minimum recommended concentration (MRC) of 1.5%. Revital-Ox RESERT HLD is intended to be used by health care practitioners in clinical settings as a ready-to-use liquid chemical disinfectant for the high level disinfection of semi-critical medical devices for which alternative methods of terminal processing are not suitable or available.
Why Revital-Ox RESERT High Level Disinfectant?
Related products used in high level disinfection include:
Revital-Ox® RESERT® R60 Solution Test Strip: The Revital-Ox RESERT R60 Solution Test Strip is a high level disinfectant concentration monitor dedicated for use with Revital-Ox™ RESERT™ High Level Disinfectant. The purpose of the Revital-Ox™ RESERT™ R60 Solution Test Strip is to determine whether the concentration of hydrogen peroxide, the active ingredient in Revital-Ox™ RESERT™ High Level Disinfectant, is above the minimum recommended concentration (MRC) of 1.5%.
Cycle Log Forms for Revital-Ox RESERT HLD: The VERDOC® RESERT HLD Solutions Processing Log Form documents: Patient ID, date/time, exposure time, temperature, items processed, and test results. The double-sided log form records 22 cycles.
*Keep the instrument or medical device immersed for a minimum of 1 minute in rinse duration unless longer is specified by the instrument manufacturer.
Browse a complete Item Number list and easily reorder Revital-Ox® RESERT® High Level Disinfectant products on Shop STERIS.
Product Number | Description | |
---|---|---|
4455AW | REVITAL-OX RESERT HIGH LEVEL DISINFECTANT (4 X 4 LTR - CASE - USA) | |
4455N9 | REVITAL-OX RESERT HIGH LEVEL DISINFECTANT (6 X 1L) | |
2D93Q0 | REVITAL-OX RIGID CONTAINER SYSTEM - (1 EACH) | |
2D94Q0 | REVITAL-OX FLEXIBLE CONTAINER (ROUND) (1 EACH) | |
RK038 | VERDOC RESERT HLD SOLUTIONS PROCESSING LOG FORMS (100/BX) | |
PCC053 | REVITAL-OX RESERT R60 STRIPS (1 BTLS/BX;60/BTL) | |
PCC054 | REVITAL-OX RESERT R60 STRIPS (2 BTLS/CS;60/BTL) |
Where can I confirm if my medical device is compatible with Revital-Ox RESERT High Level Disinfectant?
Identify semi-critical medical devices and accessories that have been tested to confirm materials compatibility with Revital-Ox RESERT High Level Disinfection using the Device Compatibility Matrix.
What should I do if my medical device is not listed on the Revital-Ox RESERT High Level Disinfectant Device Compatibility Matrix?
If a medical device is not listed on the Device Compatibility Matrix, reference the Revital-Ox RESERT High Level Disinfectant Technical Data Monograph (p. 8) for additional material compatibility information. Then, consult the medical device manufacturer to obtain additional information about the medical device material(s) in question.
Does STERIS sell a soaking bin?
STERIS sells two soaking bin systems: The Revital-Ox Flexible Container System (2D94Q0) and Revital-Ox Rigid Container System (2D93Q0).
How long can I use Revital-Ox RESERT High Level Disinfectant after opening?
After opening, the solution may be stored for use for up to 90 days (provided the 90 days do not extend past the expiration date on the container). When poured into a secondary container (i.e., basin), Revital-Ox RESERT HLD solution can be reused for up to 21 days or until its concentration falls below the minimum recommended concentration of 1.5% hydrogen peroxide. The MRC must be monitored before each use using the Revital-Ox™ Resert® R60 Solution Test Strip.
What is the shelf life of Revital-Ox RESERT High Level Disinfectant?
This product has an 18-month shelf life and needs no special venting during use or storage.
What is the difference between Aldehyde-based HLDs and Oxidative HLDs?
Aldehyde-based HLDs | Oxidative HLDs such as Revital-Ox RESERT High Level Disinfectant |
---|---|
Aldehyde-based high level disinfectants have the tendency to fixate organic soils onto medical device surfaces (1, 2) | Oxidative high level disinfectants do not fixate organic soils onto medical device surfaces (1, 2) |
Research has shown that aldehyde-based HLDs have resistance to certain microorganisms (3, 4) | Oxidative high level disinfectants have no known resistance to microorganisms3 |
Multiple rinses are required after soaking contact time | One rinse for a minimum of 1 minute unless a longer time is specified by the instrument manufacturer* |
*Always follow the instrument manufacturer’s instructions for use. Rinsing instructions referenced are for Revital-Ox RESERT High Level Disinfectant
1 Pineau, et al., Comparison of fixative properties of five disinfectant solutions. Journal of Hospital Infection (2008)
2 Meyers, et al., Letter to the Editor Advantage of pH-neutral peracetic acid over peracetic acid in reduction of viable count of biofilm / Journal of Hospital Infection Available online December 2019
3 Burgess, W., Margolis, A., Gibbs, S., et al., (2017), Disinfectant susceptibility profiling glutaraldehyde-resistant nontuberculous. mycobacteria. Infection Control & Hospital Epidemiology. p.1-8
4 Fisher, W., Fiorello, A., Shaffer., D., (2012) Aldehyde-resistant mycobacteria bacteria associated with use of endoscope reprocessing systems. American Journal of Infection Control. p 1-3.
TECHNICAL MONOGRAPH
|
|
---|---|
Document # | Document Title |
REVITAL-OX RESERT HIGH LEVEL DISINFECTANT TECHNICAL DATA MONOGRAPH | |
REVITAL-OX RESERT HIGH LEVEL DISINFECTANT TECHNICAL DATA MONOGRAPH (INT-ENGLISH) | |
REVITAL-OX RESERT HIGH LEVEL DISINFECTANT TECHNICAL DATA MONOGRAPH (SPANISH) | |
REVITAL-OX RESERT HIGH LEVEL DISINFECTANT TECHNICAL DATA MONOGRAPH (PORTUGUESE) |
TECH DATA SHEET
|
|
---|---|
Document # | Document Title |
REVITAL-OX RESERT HIGH LEVEL DISINFECTANT | |
REVITAL-OX RESERT HIGH LEVEL DISINFECTANT |
LABORATORY REPORTS
|
|
---|---|
Document # | Document Title |
REVITAL-OX RESERT HIGH LEVEL DISINFECTANT SUBSTRATE COMPATIBILITY |
SDS
|
|
---|---|
Document # | Document Title |
REVITAL-OX RESERT HIGH LEVEL DISINFECTANT-SDS-BULGARIAN | |
REVITAL-OX RESERT HIGH LEVEL DISINFECTANT-SDS-SWISS | |
REVITAL-OX RESERT HIGH LEVEL DISINFECTANT-SDS-CZECH | |
REVITAL-OX RESERT HIGH LEVEL DISINFECTANT-SDS-GERMAN | |
REVITAL-OX RESERT HIGH LEVEL DISINFECTANT-SDS-DANISH | |
REVITAL-OX RESERT HIGH LEVEL DISINFECTANT-SDS-SPANISH | |
REVITAL-OX RESERT HIGH LEVEL DISINFECTANT-SDS-FINNISH | |
REVITAL-OX RESERT HIGH LEVEL DISINFECTANT-SDS-FRENCH | |
REVITAL-OX RESERT HIGH LEVEL DISINFECTANT-SDS-GREEK | |
REVITAL-OX RESERT HIGH LEVEL DISINFECTANT-SDS-CROATIAN | |
REVITAL-OX RESERT HIGH LEVEL DISINFECTANT-SDS-HUNGARIAN | |
REVITAL-OX RESERT HIGH LEVEL DISINFECTANT-SDS-ISELANDIC | |
REVITAL-OX RESERT HIGH LEVEL DISINFECTANT-SDS-ITALIAN | |
REVITAL-OX RESERT HIGH LEVEL DISINFECTANT-SDS-LATVIAN | |
REVITAL-OX RESERT HIGH LEVEL DISINFECTANT - MALAY | |
REVITAL-OX RESERT HIGH LEVEL DISINFECTANT-SDS-DUTCH | |
REVITAL-OX RESERT HIGH LEVEL DISINFECTANT-SDS-POLISH | |
REVITAL-OX RESERT HIGH LEVEL DISINFECTANT-SDS-PORTUGUESE | |
REVITAL-OX RESERT HIGH LEVEL DISINFECTANT-SDS-SERBIAN | |
REVITAL-OX RESERT HIGH LEVEL DISINFECTANT-SDS-RUSSIAN | |
REVITAL-OX RESERT HIGH LEVEL DISINFECTANT-SDS-SWEDISH | |
REVITAL-OX RESERT HIGH LEVEL DISINFECTANT-SDS-SLOVENIAN | |
REVITAL-OX RESERT HIGH LEVEL DISINFECTANT-SDS-UNITED KINGDOM | |
REVITAL-OX RESERT HIGH LEVEL DISINFECTANT-SDS-UNITED STATES | |
REVITAL-OX RESERT HIGH LEVEL DISINFECTANT-SDS-AUSTRALIAN | |
REVITAL-OX RESERT HIGH LEVEL DISINFECTANT-SDS-JAPANESE | |
REVITAL-OX RESERT HIGH LEVEL DISINFECTANT-SDS-SPANISH FOR MEXICO | |
REVITAL-OX RESERT HIGH LEVEL DISINFECTANT-SDS-SPANISH (US) |
INSTRUCTIONS FOR USE
|
|
---|---|
Document # | Document Title |
REVITAL-OX RESERT HIGH LEVEL DISINFECTANT - IFU | |
REVITAL OX RESERT R60 SOLUTION TEST STRIP |
BROCHURE
|
|
---|---|
Document # | Document Title |
REVITAL-OX BROCHURE- US |