MEDIVATORS™ ADVANTAGE PLUS™ Pass-Thru Automated Endoscope Reprocessor
- Cycles: Validated high-level disinfection (HLD) after manual cleaning
- Workflow: Pass-thru endoscope reprocessing with no-touch workflow to reduce cross-contamination
- Capacity: Asynchronous bays allow you to HLD endoscopes individually in a 35-39 minute cycle
The MEDIVATORS ADVANTAGE PLUS Pass-Thru Automated Endoscope Reprocessor (AER) allows you to meet the recommendations for unidirectional pass-thru processing. It is the first pass-thru dual basin system for HLD, enabling you to process two endoscopes at separate times, improving reprocessing efficiency.
The ADVANTAGE PLUS Pass-Thru AER is part of the STERIS No-Touch Workflow with ADVANTAGE Transport Cassettes that allow endoscopes to be transported with minimal endoscope handling to reduce the risk of cross-contamination and damage.
How the MEDIVATORS ADVANTAGE PLUS Pass-Thru Automated Endoscope Reprocessor Works
The MEDIVATORS ADVANTAGE PLUS Pass-Thru AER improves adherence to established industry guidelines for endoscope disinfection. It has been proven to high-level disinfect a wide variety of the most commonly used endoscopes. This automatic endoscope reprocessor uses the non-enzymatic INTERCEPT™ PLUS Detergent in the wash cycle before disinfection to effectively loosen soils in three minutes at 68-95°F (20-35°C). During the automated cycle, the system also uses single-use RAPICIDE™ PA High-Level Disinfectant to effectively kill TB, hepatitis viruses, C-diff, VRE, MRSA, and CRE in five minutes at 86°F (30°C).

Why the MEDIVATORS ADVANTAGE PLUS Pass-Thru Automated Endoscope Reprocessor?
- Convenient transport cassette reduces handling and helps prevent endoscope damage and recontamination.
- Features a hands-free operation and automatic cycle start.
- Continuous leak testing during a cycle, the endoscope reprocessor high-level disinfects leaky or damaged endoscopes before servicing.
- Ergonomic design and large, easy-loading basins support operator comfort.
- Remote diagnostics enable fast and efficient technical support and servicing, maximizing reprocessor availability.
- Large visual display of real-time cycle information.
- Barcode scanner for fast and accurate data entry (e.g., endoscope, operator, patient, and physician IDs) to facilitate cycle management and endoscope traceability.
- Computerized cycle documentation and reporting. The pass-thru AER integrates with SPM® Endo Workflow Solutions software and other tracking software solutions for active monitoring and process verification.
Accessories
MEDIVATORS ADVANTAGE PLUS Pass-Thru Automated Endoscope Reprocessor Accessories
| Part Number | Description | |
|---|---|---|
| ML020145 | INTERCEPT PLUS Detergent (2 bottles/case) | |
| ML020117 (USA) | RAPICIDE PA High-Level Disinfectant (4 bottles/case - 2 Part A, 2 Part B) | |
| ML020116 (Canada) | RAPICIDE PA High-Level Disinfectant (4 bottles/case - 2 Part A, 2 Part B) | |
| ML020118 | RAPICIDE PA Test Strips (2 bottles/pack - 100 strips/bottle) | |
| CAS1000 | Endoscope Transport Cassette |
|
SDS
|
|
|---|---|
| Document # | Document Title |
| INTERCEPT PLUS DETERGENT-SDS-UNITED STATES | |
| INTERCEPT PLUS DETERGENT-SDS-CANADIAN | |
| INTERCEPT PLUS DETERGENT-SDS-SLOVENIAN | |
| INTERCEPT PLUS DETERGENT-SDS-FINNISH | |
| INTERCEPT PLUS DETERGENT-SDS-POLISH | |
| INTERCEPT PLUS DETERGENT-SDS-GERMAN | |
| INTERCEPT PLUS DETERGENT-SDS-DANISH | |
| INTERCEPT PLUS DETERGENT-SPANISH | |
| INTERCEPT PLUS DETERGENT-SPANISH FOR LATIN AMERICA | |
| INTERCEPT PLUS DETERGENT-FRENCH | |
| INTERCEPT PLUS DETERGENT-ITALIAN | |
| INTERCEPT PLUS DETERGENT-DUTCH | |
| INTERCEPT PLUS DETERGENT-NORWEGIAN | |
| INTERCEPT PLUS DETERGENT-PORTUGUESE | |
| INTERCEPT PLUS DETERGENT-SWEDISH | |
| INTERCEPT PLUS DETERGENT-SDS-INTERNATIONAL ENGLISH | |
|
TECH DATA SHEET
|
|
|---|---|
| Document # | Document Title |
| ADV+ PT TECH DATA SHEET (NA) | |
|
OPERATORS MANUAL
|
|
|---|---|
| Document # | Document Title |
| MEDIVATORS ADVANTAGE PLUS PASS-THRU (US) | |
|
TECHNICAL MONOGRAPH
|
|
|---|---|
| Document # | Document Title |
| RAPICIDE PA | |
|
SELL SHEET
|
|
|---|---|
| Document # | Document Title |
| INTERCEPT PLUS DETERGENT SELL SHEET | |
|
BROCHURE
|
|
|---|---|
| Document # | Document Title |
| ADVANTAGE PLUS PASS-THRU SYSTEM BROCHURE | |
| ADVANTAGE PLUS PASS-THRU SYSTEM BROCHURE (CANADA) | |
| ADVANTAGE PLUS PASS-THRU SYSTEM BROCHURE (FRENCH) | |
| GI REPROCESSING PORTFOLIO BROCHURE | |