The MEDIVATORS ADVANTAGE PLUS Pass-Thru Automated Endoscope Reprocessor is the first pass-thru platform to physically separate the areas of flexible endoscope reprocessing rooms.
How the MEDIVATORS ADVANTAGE PLUS Pass-Thru Automated Endoscope Reprocessor Works
The physical separation of the clean and dirty environments within an endoscope reprocessing area is a globally-recognized infection prevention best practice1 that helps reduce the risk of recontamination, helping to ensure patient-ready endoscopes for every procedure.
Using an effective detergent and disinfectant is necessary for removing bioburden and contaminants from endoscopes. The MEDIVATORS ADVANTAGE PLUS Pass-Thru Automated Endoscope Reprocessor uses the non-enzymatic INTERCEPT™ PLUS Detergent in the wash cycle before disinfection to effectively loosen soils in three minutes at 68-95°F (20-35°C). During the automated cycle, the system also uses the single-use, non-aldehyde RAPICIDE™ PA High-Level Disinfectant to effectively kill TB, hepatitis viruses, C-diff, VRE, MRSA and CRE in five minutes at 86°F (30°C).
The MEDIVATORS ADVANTAGE PLUS Pass-Thru Automated Endoscope Reprocessor improves adherence to established industry guidelines for disinfection2,3,4 and has been proven to high-level disinfect a wide variety of the most commonly used endoscopes.
Find the Medivators Hook-Up Guide Here or Medivators IFUs Here.
Why the MEDIVATORS ADVANTAGE PLUS Pass-Thru Automated Endoscope Reprocessor?
MEDIVATORS ADVANTAGE PLUS Pass-Thru Automated Endoscope Reprocessor Accessories
Part Number | Description |
---|---|
ML020145 | INTERCEPT PLUS Detergent (2 bottles/case) |
ML020117 (USA) | RAPICIDE PA High-Level Disinfectant (4 bottles/case - 2 Part A, 2 Part B) |
ML020116 (Canada) | RAPICIDE PA High-Level Disinfectant (4 bottles/case - 2 Part A, 2 Part B) |
ML020118 | RAPICIDE PA Test Strips (2 bottles/pack - 100 strips/bottle) |
CAS1000 | Endoscope Transport Cassette |
1: UK Department of Health (2016). Health Technical Memorandum 01-06: Decontamination of flexible endoscopes: Part B – Design and installation. Retrieved from: https://www.gov.uk/government/uploads/system/uploads/attachment_data/file/530420/HTM0106_PartB.pdf
2: UK Department of Health (2016). Health Technical Memorandum 01-06: Decontamination of flexible endoscopes: Part B – Design and installation. Retrieved from: https://www.gov.uk/government/uploads/system/uploads/attachment_data/file/530420/HTM0106_PartB.pdf
3: Association for the Advancement of Medical Instrumentation and American National Standards Institute (2015). ANSI/AAMI ST91:2015 Flexible and semi-rigid endoscope processing in health care facilities.
4: Society of Gastroenterology Nurses and Associates (2012). Standards of Infection Control in Reprocessing of Flexible Gastrointestinal Endoscopes. Retrieved from: https://www.sgna.org/Portals/0/Education/PDF/Standards-Guidelines/sgna_stand_of_infection_control_0812_FINAL.pdf
SDS
|
|
---|---|
Document # | Document Title |
INTERCEPT PLUS DETERGENT-SDS-UNITED STATES | |
INTERCEPT PLUS DETERGENT-SDS-CANADIAN | |
INTERCEPT PLUS DETERGENT-SDS-SLOVENIAN | |
INTERCEPT PLUS DETERGENT-SDS-FINNISH | |
INTERCEPT PLUS DETERGENT-SDS-POLISH | |
INTERCEPT PLUS DETERGENT-SDS-GERMAN | |
INTERCEPT PLUS DETERGENT-SDS-DANISH | |
INTERCEPT PLUS DETERGENT-SPANISH | |
INTERCEPT PLUS DETERGENT-SPANISH FOR LATIN AMERICA | |
INTERCEPT PLUS DETERGENT-FRENCH | |
INTERCEPT PLUS DETERGENT-ITALIAN | |
INTERCEPT PLUS DETERGENT-DUTCH | |
INTERCEPT PLUS DETERGENT-NORWEGIAN | |
INTERCEPT PLUS DETERGENT-PORTUGUESE | |
INTERCEPT PLUS DETERGENT-SWEDISH | |
INTERCEPT PLUS DETERGENT-SDS-INTERNATIONAL ENGLISH |
TECHNICAL MONOGRAPH
|
|
---|---|
Document # | Document Title |
RAPICIDE PA |
SELL SHEET
|
|
---|---|
Document # | Document Title |
INTERCEPT PLUS DETERGENT SELL SHEET |
BROCHURE
|
|
---|---|
Document # | Document Title |
ADVANTAGE PLUS PASS-THRU SYSTEM BROCHURE | |
ADVANTAGE PLUS PASS-THRU SYSTEM BROCHURE | |
ADVANTAGE PLUS PASS-THRU SYSTEM BROCHURE |