Electro Lube™ NXT is a second-generation surgical anti-stick solution specifically designed for precision electrosurgery. Its familiar yet enhanced performance will minimize the challenges of eschar while also reducing cutting force and tissue sticking.
How Electro Lube NXT Works
Electrosurgery is commonly used across most surgical disciplines. However, it can have negative impacts while in use and create challenges during the reprocessing of electrosurgical instruments. As heated instruments contact tissue, resistance in cutting force can develop, resulting in tissue buildup known as eschar. Eschar negatively affects the performance of the surgical instrument by impeding current flow and can be difficult to remove.
Electro Lube NXT is an anti-stick solution designed to be applied to electrosurgical instrument tips to reduce occurrences of electrode adhesion to tissue at the surgical site and to reduce the amount of eschar that forms with each burn. This allows surgeons to perform more cuts before the electrode needs to be handed back for cleaning and aids in eschar removal.
Why Choose Electro Lube NXT?
Electro Lube NXT has been validated for reprocessability with reusable electrosurgical instruments to optimize patient and staff safety. It has also been validated for use with robotic instruments.
With Electro Lube™ NXT
With Electro Lube™
Without Electro Lube™
Electro Lube™ NXT | Electro Lube™ | |
---|---|---|
*Compared to the uncoated electrode | ||
Validated for use on Robotic Instruments | Yes | No |
Reduction in Cutting Force* | 71% | 48% |
Reduction in Tissue Sticking* | 70% | 40% |
Reduction in Eschar Accumulation | 39% | 35% |
Validated Thermal Spread Performance (In accordance with FDA Guidance) |
Yes | No |
Validated Reprocessing (In accordance with ST98) |
Yes | No |
INSTRUCTIONS FOR USE
|
|
---|---|
Document # | Document Title |
ELECTRO LUBE NXT - IFU |
SELL SHEET
|
|
---|---|
Document # | Document Title |
ELECTRO LUBE NXT REFERENCE SHEET |
TECHNICAL MONOGRAPH
|
|
---|---|
Document # | Document Title |
TECHNICAL DATA MONOGRAPH - CLINICAL AND REPROCESSING BENEFITS OF ELECRO LUBE NXT ELECTROSURGICAL ANTI-STICK SOLUTION |
SDS
|
|
---|---|
Document # | Document Title |
ELECTRO LUBE NXT SAFETY DATA SHEET |