SYSTEM 1E Liquid Chemical Sterilant Processing
SYSTEM 1E Liquid Chemical Sterilant Processing
Cart-mounted for ease of installation
Cart-mounted for ease of installation
Liquid chemical sterilization of duodenoscopes
Liquid chemical sterilization of duodenoscopes
S40 sterilant concentrate as a validated process
S40 sterilant concentrate as a validated process

SYSTEM 1E® Liquid Chemical Sterilant Processing System

  • For safe and effective reprocessing of heat-sensitive critical and semi-critical devices
  • The only practical solution for low temperature sterilization of complex heat-sensitive flexible endoscopes, such as duodenoscopes
  • Rapid 23 minute cycle time
  • Utilizes S40™ Sterilant Concentrate which eliminates all microbial life, including bacterial endospores
 
SYSTEM 1E Liquid Chemical Sterilant Processing System "Effectiveness of the SYSTEM 1E Liquid Chemical Sterilant Processing System for reprocessing duodenoscopes"*

*American Journal of Infection Control (2016).

SYSTEM 1E® Liquid Chemical Sterilant Processing System

The SYSTEM 1E Liquid Chemical Sterilant Processing System is for safe and effective reprocessing of heat-sensitive critical and semi-critical devices and is the only practical solution for low temperature sterilization of complex flexible endoscopes, such as duodenoscopes used in endoscopic retrograde cholangiopancreatography (ERCP) procedures.

How SYSTEM 1E® Liquid Chemical Sterilant Processing System Works

Liquid chemical sterilization enables rapid, efficacious reprocessing for cleaned, reusable, immersible, and heat-sensitive critical and semi-critical devices. The system utilizes S40™ Sterilant Concentrate to eliminate all microbial life, including bacterial endospores. The S1E processor, two pre-filters, UV irradiation and a MaxPure™ filter work in harmony with S40 Sterilant Concentrate to provide a validated process for critical and semi-critical, heat sensitive devices. The gentle use-dilution protects delicate surgical instruments, including multi-channel flexible surgical endoscopes. The use-dilution is neutral pH, and rinses safely down the drain. Quick Connect adapters are designed to leak to ensure sterilant use dilution reaches all surfaces and angles of the device ports.

Why SYSTEM 1E® Liquid Chemical Sterilant Processing System?

The SYSTEM 1E processor will help you process your devices with confidence. Its compact footprint and rapid 23 minute cycle time makes it convenient and ideal for a variety of locations. Compared to high-level disinfection, it provides a higher level of reprocessing assurance for heat-sensitive critical and semi-critical devices such as flexible or semi-rigid endoscopes.

 

Device Compatibility Matrix

Confirm that your medical devices and accessories are compatible for processing with our
Low Temperature Systems.

Begin Device Compatibility Matrix

BROCHURE
Document # Document Title
Requires Adobe Reader  M3432EN SYSTEM 1E LIQUID CHEMICAL STERILANT PROCESSING SYSTEM
Requires Adobe Reader  M3499EN SYSTEM 1 AND 1E WARNING LABELS-IN PACKS OF 10 EACH OF 2 SYSTEM 1 AND 20 EACH OF 2 SYSTEM 1E LABELS
Requires Adobe Reader  M4281EN SYSTEM 1E LIQUID CHEMICAL STERILANT PROCESSING BROCHURE GI FOCUS
Requires Adobe Reader  M7575EN QUICK TURN CENTER BROCHURE
MSDS
Document # Document Title
Requires Adobe Reader  S288 VERIFY CHEMICAL INDICATOR FOR SYSTEM 1E LIQUID CHEMICAL STERILANT PROCESSING SYSTEM
SELL SHEET
Document # Document Title
Requires Adobe Reader  M4278EN SYSTEM 1E SELL SHEET
M4273EN SAMPLE PROCEDURES - USE OF OPTIONAL ACCESSORIES FOR THE SYSTEM 1E® LIQUID CHEMICAL STERILANT PROCESSING SYSTEM
TECH DATA
Document # Document Title
Requires Adobe Reader  SD924 SYSTEM 1E LIQUID CHEMICAL STERILANT PROCESSING SYSTEM
TECHNICAL MONOGRAPH
Document # Document Title
Requires Adobe Reader  T6530B TECHNICAL DATA MONOGRAPH FOR SYSTEM 1E LIQUID CHEMICAL STERILANT PROCESSING SYSTEM
WALL CHART
Document # Document Title
Requires Adobe Reader  M3509EN VERIFY CHEMICAL INDICATOR FOR SYSTEM 1E PROCESSOR WALL CHART
Requires Adobe Reader  M3692EN SPORE KILL TESTING IN THE SYSTEM 1E LIQUID CHEMICAL STERILANT PROCESSING SYSTEM WALL CHART
Requires Adobe Reader  M3681EN SYSTEM 1E LIQUID CHEMICAL STERILANT PROCESSING SYSTEM WATER TREATMENT GUIDE
Requires Adobe Reader  M3498EN PROPER CONSUMABLE SELECTION FOR SYSTEM 1E AND SYSTEM 1 PROCESSORS WALL CHART

Share this page

STERIS Replacement Parts for your STERIS SYSTEM 1E Systems

Enter Your Zip Code to Locate Your Sales Representative


Subscribe to
our mailing list

Receive customized email communications from STERIS


Device Compatibility Matrix

Confirm that your medical devices and accessories are compatible for processing with our Low Temperature Systems.

Search for my devices