The VERIFY Biological/Integrator Challenge Packs are the best of both worlds.
The VERIFY Biological/Integrator Challenge Packs are the best of both worlds.
Each challenge pack contains a biological indicator, integrator and steam barrier materials.
Each challenge pack contains a biological indicator, integrator and steam barrier materials.
The VERIFY Steam Integrator is correlated to biological indicator kill and provides immediate knowledge of sterilization failures.
The VERIFY Steam Integrator is correlated to biological indicator kill and provides immediate knowledge of sterilization failures.
Compact design allows placement of an additional sterilization container not possible with larger test pack designs.
Compact design allows placement of an additional sterilization container not possible with larger test pack designs.
VERIFY Biological Indicator System fits easily into work stations.
VERIFY Biological Indicator System fits easily into work stations.
Bright yellow color change makes identifying positive biological indicator growth easier.
Bright yellow color change makes identifying positive biological indicator growth easier.
Clear blue media means no biological indicator growth, a passing test.
Clear blue media means no biological indicator growth, a passing test.
The VERIFY Activator makes sealing and crushing of the Biological Indicator easy.
The VERIFY Activator makes sealing and crushing of the Biological Indicator easy.
VERIFY Incubators range from 6 wells to 28 wells for your biological indicator incubation needs.
VERIFY Incubators range from 6 wells to 28 wells for your biological indicator incubation needs.

VERIFY Biological/Integrator Challenge Pack

VERIFY┬áBiological/Integrator Challenge Packs are used to release dynamic air removal (prevacuum and steam-flush pressure-pulse) steam sterilization (autoclave) cycles performed at 270°F/132°C and gravity cycles performed at 250°F/121°C.

 

request a quote

 

Don't waste precious sterilizer space; use the compact VERIFY Biological/Integrator Challenge Pack.

VERIFY Biological/Integrator Challenge Packs are used to release dynamic air removal (prevacuum and steam-flush pressure-pulse) steam sterilization (autoclave) cycles performed at 270°F/132°C and gravity cycles performed at 250°F/121°C. The VERIFY  Biological/Integrator Challenge Pack is equivalent to the AAMI 16-towel biological indicator test pack. Each pack contains a Class 5 chemical integrator, as defined by ANSI/AAMI/ISO 11140-1 and a VERIFY Self-Contained Biological Indicator.

  • Integrator provides immediate knowledge of sterilization failures
  • 24-hour final release
  • Class 5 chemical integrator meets ANSI/AAMI/ISO 11140-1 requirements
  • Equivalent to an ANSI/AAMI ST79 16-Towel Biological Indicator Test Pack
  • For routine monitoring, qualification and release of loads containing implantable devices
Product Number Description Quantity
LCB006
VERIFY™ Biological/Integrator Challenge Pack
Box (20 packs and 5 controls)
LCB007 VERIFY™ Biological/Integrator Challenge Pack
Box (20 packs and 20 controls)
 
Document # Document Title
S116UK VERIFY SCBI AND TEST PACKS - UNITED KINGDOM
S116IT VERIFY SCBI AND TEST PACKS - ITALIAN
S116PT VERIFY SCBI AND TEST PACKS - PORTUGUESE
S116 VERIFY SCBI AND TEST PACKS
B108 VERIFY BIOLOGICAL/INTEGRATOR CHALLENGE PACK AND VERIFY INTEGRATING INDICATOR
 
MSDS
Document # Document Title
Requires Adobe Reader  S116UK
VERIFY SCBI AND TEST PACKS - UNITED KINGDOM
Requires Adobe Reader  S116IT
VERIFY SCBI AND TEST PACKS - ITALIAN
Requires Adobe Reader  S116PT
VERIFY SCBI AND TEST PACKS - PORTUGUESE
Requires Adobe Reader  S116
VERIFY SCBI AND TEST PACKS
Requires Adobe Reader  B108
VERIFY BIOLOGICAL/INTEGRATOR CHALLENGE PACK AND VERIFY INTEGRATING INDICATOR
TECH DATA SHEETS
Document # Document Title
VERIFY DUAL TEMPERATURE 28-WELL INCUBATOR (220 VAC) FOR VERIFY SELF-CONTAINED BIOLOGICAL INDICATORS (S3081)
VERIFY DUAL TEMPERATURE 28-WELL INCUBATOR FOR VERIFY SELF-CONTAINED BIOLOGICAL INDICATORS (S3080)
VERIFY SINGLE TEMPERATURE 28-WELL INCUBATOR FOR VERIFY SELF-CONTAINED BIOLOGICAL INDICATORS (S3082)
TECHNICAL TIPS
Document # Document Title
TECHNICAL TIP 5501 - COLOR REVERSION OF VERIFY DUAL SPECIES SELF-CONTAINED BIOLOGICAL INDICATORS

An incubator and activator set are required for proper use of the Verify Biological/Integrator Challenge Packs.

Product Number Description Quantity
S3075
VERIFY™ Vial Activator Set
Each
S3080 VERIFY™ 8 Well Dual Incubator (55-60°C and 35-39°C)
Each
S3082 VERIFY™ 28 Well Incubator for Steam (55-60°C)
Each
S3271 VERIFY™ 6 Well Steam Incubator (55-60°C)
Each
SKU #: LCB006
Log in to see price
add to cart Quantity
Share this page

Enter Your Zip Code to Locate Your Sales Representative


Subscribe to
our mailing list

Receive customized email communications from STERIS



 
STERIS Corporation

STERIS is a leading provider of infection prevention
and other procedural products and services.

5960 Heisley Road, Mentor, OH 44060 U.S.A.

800.548.4873 or 440.354.2600

QUICK LINKS

Careers

Investors

News

 
Code of Ethics

steris.com

© Copyright 2018, STERIS plc. All rights reserved.
Registered in England and Wales No. 09257343.
Registered office: Rutherford House, Stephensons Way,
Derby DE21 6LY, United Kingdom