AMSCO® V-PRO® maX Low Temperature Sterilization System

V-PRO maX - A Customer Solution that is above the curve.

V-PRO maX - A Customer Solution that is above the curve. 1 sterilizer, 3 cycles gives you maximum versatility Sterilant, 15 cycles/cup Large Chamber = More Capacity Easy Open Door - Just pull and push, no handle. Process 2 Surgical Flexible Scopes (or) 1 Surgical Flexible Scope and non lumened load up to 24 pounds.

Additional Images (Mouse over to view larger)

Above the Curve

Introducing AMSCO® V-PRO® maX
Low Temperature Sterilization System

Above the Curve in Versatility

  • Process dual channel surgical flexible endoscopes
  • Processing options include a 35-minute Flexible Cycle, a 55-minute Lumen Cycle and a
    28-minute Non Lumen Cycle.

Device Matrix

 

Above the Curve in Productivity

  • 136 L of usable chamber space
  • Process up to 2X more Lumen devices* per load than STERRAD 100NX and NX
  • Process 2 Surgical Flexible Scopes (or) 1 Surgical Flexible Scope and non lumened load up to 24 pounds.

*As of October 1, 2011 STERRAD 100NX and NX are cleared to process 10 stainless steel lumens per load, V-PRO maX is cleared to process 20 stainless steel lumens per load.

STERRAD is a registered trademark of Advanced Sterilization Products, a Johnson & Johnson Company.

 
Document # Document Title
A124 VAPROX HC STERILANT (59% HYDROGEN PEROXIDE)
 
Brochure
Document # Document Title
M3267EN CONSUMABLES FOR V-PRO LOW TEMPERATURE STERILIZATION SYSTEMS
M3583EN AMSCO V-PRO MAX INDICATIONS FOR USE
M3586EN INTRODUCING AMSCO V-PRO MAX
M3597EN V-PRO MAX LOW TEMPERATURE STERILIZATION SYSTEM FULL BROCHURE
M3644EN V-PRO TOTAL DOSE COMPARISON CHART
M3752GB DONT ADD COMPLEXITY WITH PLASMA- V-PRO STERILIZERS
M3855ES-MX CONSUMABLES FOR V-PRO LOW TEMPERATURE STERILIZATION SYSTEMS-SPANISH FOR MEXICO
M3855PT CONSUMABLES FOR V-PRO LOW TEMPERATURE STERILIZATION SYSTEMS-PORTUGUESE FOR BRAZIL
Label
Document # Document Title
A124L VAPROX HC STERILANT (59%HYDROGEN PEROXIDE)
Laboratory Reports
Document # Document Title
450-300-5003 VALIDATION OF DOUBLE POUCH MICROBIAL EFFICACY IN THE AMSCO V-PRO 1/V-PRO 1 PLUS/V-PRO MAX LOW TEMP STERILIZATION SYSTEMS - INTERNATIONAL USE ONLY
450-300-5505 VALIDATION OF DOUBLE POUCH MICROBIAL EFFICACY IN THE AMSCO V-PRO 1/V-PRO 1 PLUS/V-PRO MAX LOW TEMPERATURE STERILIZATION SYSTEMS - US USE ONLY
SDS
Document # Document Title
A124 VAPROX HC STERILANT (59% HYDROGEN PEROXIDE)
Sample Procedures
Document # Document Title
M3815CA SAMPLE PROCEDURE FOR CANADA USE ONLY: MICROBIAL VERIFICATION FOLLOWING INSTALLATION OR MAJOR REPAIR OF V-PRO 1, 1 PLUS, & MAX- LCB024, LCB004
M3815EN SAMPLE PROCEDURE FOR CANADA USE ONLY: MICROBIAL VERIFICATION FOLLOWING INSTALLATION OR MAJOR REPAIR OF V-PRO 1, 1 PLUS, & MAX- LCB024, LCB004
Sell Sheet
Document # Document Title
M3584EN AMSCO V-PRO STERILIZATION SYSTEM QUICK REFERENCE GUIDE - LONG
M3593EN AMSCO V-PRO MAX 3-YEAR EXTENDED WARRANTY
M3800EN V-PRO MAX STERILIZATION SYSTEM QUICK REFERENCE GUIDE - VS. STERRAD NX
Tech Data
Document # Document Title
SD931 AMSCO V-PRO MAX LOW TEMPERATURE STERILIZATION SYSTEM (FOR USE OUTSIDE U.S.A. ONLY)
SD949 AMSCO V-PRO MAX LOW TEMPERATURE STERILIZATION SYSTEM (FOR USE IN U.S.A. ONLY)
Technical Monograph
Document # Document Title
M3635EN AMSCO V-PRO MAX LOW TEMPERATURE STERILIZATION SYSTEM TECHNICAL DATA MONOGRAPH
Wall Chart
Document # Document Title
M3374ES-MX BIOLOGICAL MONITORING OF THE AMSCO V-PRO 1, V-PRO 1 PLUS AND V-PRO MAX LOW TEMPERATURE STERILIZERS-SPANISH FOR MEXICO
M3646CA GUIDELINES FOR PREPARATION PACKING AND LOADING OF AMSCO V-PRO LOW TEMPERATURE STERILIZATION SYSTEMS
M3646EN GUIDELINES FOR PREPARATION, PACKING AND LOADING OF AMSCO V-PRO LOW TEMPERATURE STERILIZATION SYSTEMS