  Browne TST Bowie Dick Single Use Test Pack

The TST Bowie Dick Single Use Test Pack is an accepted method of testing the steam penetration and air removal capability of a vacuum steriliser. The TST indicator system is diagnostic which helps you to speed up fault detection and steriliser repair times. Conforms to EN867-4 (The European standard for alternative BD Tests, BSI Kitemarked and manufactured to ISO 9001:2000 & ISO 13485:2003.
 
 
  Browne TST Helix

The TST Helix has been developed and validated for testing the air removal (steam penetration) capability of small Type B steam sterilisers only. A successful test confirms steam penetration through the helix and confirms by implication that air and other non-condensable gases have been removed. Conforms to EN867-5 for use in performance testing for small sterilisers Type B and EN 554: 1994.
 
 
  Browne TST Control

The TST Control Cycle Verification Indicators provide the most specific information of any chemical indicator available. All Indicators have been calibrated to perform to the predefined parameters of a particular process, helping the end users detect process failure by confirming that all of the predetermined cycle parameters have occurred at point of placement in each tray, pack or pouch. All conform to ISO 11140-1 Class 6 Indicators and manufactured to ISO 9001:2000 & ISO 13485:2003. The Des-Check range provides an accurate, convenient method of routine control for moist heat processes. TST Control Cycle Verification (Emulating) Indicators allows the user to single out individual trays, packs or pouches that were not exposed to sufficient sterilisation conditions. TST Control Duplex Label and TST Control Multi-Part Label can create a direct link between the patient, the instruments and in pack evidence of an effective sterilisation cycle.

 
 
  Browne Multi-Parameter Indicators

The Multi-Parameter Indicators will change colour when exposed to the sterilant/disinfectant providing users with clear reassurance that the agent has penetrated to the point of placement in each tray, pack or pouch. All conform to ISO 11140-1 Class 4 Indicators. Formaldehyde Control Indicators should be used inside each pack to show that Low Temperature Steam and Formaldehyde gas (LTSF) has penetrated the pack in a sufficient quantity and for the correct length of time for sterilisation to occur. MVI Ethylene Oxide Indicators can be used in all current ethylene oxide sterilisation processes. MVI Steam Indicators can confirm that steam has penetrated to the point of placement. Vapour Strips is intended for the monitoring of the STERRAD Sterilisation System.
 
 
  Browne Ethylene Oxide Integrating Indicators

The Ethylene Oxide Integrating Indicators provides users with clear visual reassurance that the agent has penetrated to the point of placement in each tray, pack or pouch. It will show a fail if the relative humidity level, gas concentration, temperature or duration of exposure falls outside of the specified limits. Not calibrated as an in-pack control indicator. Conforms to ISO 11140-1 Class 5 Indicators.
 
 
  Verify Self-Contained Biological Indicators

The Verify Self-Contained Biological Indicators for steam and EO contain both Geobacillus stearothermophilus and Bacillus artophaeus spores and eliminate the need for aseptic transfer. They can be used in steam 121C (250F) gravity (including flash 132C (270F)), 132C (270F) prevacumm, 132C (270F) gravity Flash 132C (270F) prevacumm cycle and ethylene oxide sterilisation processes including 100% ethylene oxide applications. With a sturdy construction which protects the glass media ampoule from premature breakages and easy to use activator, the final read is 24 hour incubation for steam and 48 hour incubation for EO.
 
 
  Verify Steam Integrator Strips

The Verify Steam Integrator Strips are for use in all steam sterilisation cycles and are correlated to biological indicator inactivation. The Chemical Integrators monitor all critical parameters of steam sterilisation (exposure time, temperature and steam quality). Placed in every sterilised pack, the Integrator confirms that all sterilisation conditions were met within the pack that would have inactivated a biological indicator.
 
 
  Verify Self-Contained Biological Indicators (SCBIs)

The Verify Self-Contained Biological Indicator System is designed to monitor steam and/or ethylene oxide (EO) sterilisation processes. Each Verify SCBI consists of a plastic cap and vial containing a disc carrying Geobacillus stearothermophilus (steam) (GST) and Bacillus atrophaeus (EO) (BA) spores and an ampule of bacterial culture medium combined with a pH indicator. In addition, these biological indicators are available in single species E6 populations. A colour change from blue to yellow after activation and incubation gives unmistakable evidence of microbial growth. The chemical process indicator printed on each Verify SCBI vial label shows that minimal process parameters were attained. Each lot of Verify SCBIs is produced under tightly controlled conditions and thoroughly tested to ensure compliance with STERISs strict quality requirements.
 
 


  Verify Process Challenge Devices

Verify Process Challenge Devices are available in both ethylene oxide (EO) and steam test packs. Process challenge devices are critical in simulating worst-case conditions when performing cycle development. The Verify EO and Steam Test Packs were developed to represent a greater resistance than the AAMI 16 towel biological test pack. The Verify Test Packs utilise the Verify SCBIs as well as a chemical indicator or record card. Each box includes 20 test packs and 5 controls.
 
 




  Spordex and Spordi Strips and Discs

Spordex and Spordi Strips and Discs are specifically designed for determining the effectiveness of steam, ethylene oxide (EO), dry heat, or vaporised hydrogen peroxide decontamination procedures. Each strip and disc is produced from a special filter paper or polymer substrate inoculated with bacterial spores. Biological Indicators with known resistances and spore populations ensure consistent sterility monitoring. Spordex Strips and Discs are available with either Bacillus atrophaeus (BA) for ethylene oxide or dry heat cycles, or Geobacillus stearothermophilus (GST) for saturated steam or vaporised hydrogen peroxide cycles. Spordi Strips and Discs are inoculated with both B.atrophaeus and G. stearothermophilus. This minimises stocking problems because they can be used to check the efficacy of steam, EO and dry heat sterilisers. Individual Spordex and Spordi Strips are sealed in clearly identified sterilisable glassine packages.
 
 


  Spordex Suspensions

Spordex Suspensions contain bacterial spores in a liquid suspension. It is manufactured to meet the same rigorous standards as Spordex/ Spordi Strips and Discs and contains no extraneous contamination that could affect performance. A certificate of analysis containing population and D-value is furnished with each lot. The suspension is available with spores of Bacillus atrophaeus (BA) for ethylene oxide (EO) gas and dry heat cycles, or Geobacillus stearothermophilus (GST) for saturated steam or vaporised hydrogen peroxide cycles. Spordex Suspension is sold in 10 mL vials (approximately 100 product inoculations), each furnished in an easy-to-use kit including a 1.0 mL disposable sterile syringe and instruction pamphlet.
 
 
  Spordex Culture Media

Spordex Culture Media has been developed to be used with STERIS Spordex and Spordi Biological Indicator Strips and Discs. Spordex Culture Media consists of a modified soybean casein digest broth, which contains a pH indicator. An easy-to-read colour change in the medium from red to yellow is indicative of microbial growth.
 
 






  Verify and Process Chemical Indicators

Chemical Indicators are designed to monitor penetration of steam, ethylene oxide (EO), dry heat, and vaporised hydrogen peroxide sterilisation into sterilised packages.


Verify Standard Series of Chemical Integrators

Correlated to biological indicator inactivation, the Verify Integrator Strips confirm that all the critical parameters of sterilisation have been achieved that would have inactivated (killed) a biological indicator.


Verify C5 Series of Chemical Integrators

The targeted, temperature-specific Class 5 steam integrators meet AAMI ST60 and ISO 11140 standards for integrating indicators. The easy-to-read yellow to blue colour change occurs at the end of the exposure over a short period of time.


The Steraffirm Steam Class 6 Emulating Indicators

The Steraffirm Steam Class 6 Emulating Indicators are cycle verification indicators that confirm the presence or absence of specific time/temperature parameters during a cycle. Emulating indicators may be placed inside each pack or pouch during sterilisation of supplies or equipment in a validated prevacuum cycle. Steraffirm Class 6 Emulating indicators are lead free and non toxic. The Steraffirm Class 6 Emulating indicators conform to EN 867-1 Class D and ISO 11140- 1:1995 (Class 6) standards.


Steraffirm Control Tubes for Steam and Dry Heat Sterilisation

The Control Tubes are calibrated to respond to specific temperature/time parameters during a dry or moist heat sterilisation cycle. They have a permanent colour change when the proper parameters are achieved at the location of each Control Tube. The Control Tubes for steam for use at 121C can be used to monitor liquid cycles. The Control Tubes for dry heat are calibrated to some of the more commonly used time/ temperature parameters of dry heat sterilisation.
 
 


  SteamTape and GasTape Process Indicator Tapes

SteamTape and GasTape Process Indicator Tapes are available for use in securing wrapped packs for steam and ethylene oxide sterilisation. The tape surface can be written on with indelible ink without smearing or bleeding. The chemical indicator lines show a strong, sharp colour change after processing.
 
 
  Steraffirm Bowie Dick Test Packs

The Steraffirm Bowie Dick Test packs are pre-assembled single-use test packs designed to verify the air removal effectiveness of a scientific prevacuum steriliser. Several versions of the Sterrafirm Bowie Dick Test Packs are available, and they are calibrated to be compatible with prevacuum cycles operating at specific exposure temperatures, or within a specifiied exposure temperature range. The Sterrafirm Bowie Dick Test packs conform to the EN 867-4:2001 (Class B) or ANSI/AAMI ST66 standards.
 
 


  Air Removal (Bowie-Dick) Tests

Dart Daily Air Removal Tests confirm that prevacuum steam sterilisers can effectively remove air to allow steam penetration. Whether you choose the unique compact barrel design of the Daily Air Removal Test, the lead free design of the Steraffirm Bowie-Dick Test Pack, the economical Verify Bowie-Dick Test Card or construct your own packs with the Chemdi Daily Record Sheet, you will have reliable confirmation of air removal and steam penetration.
 
 


  Vis-U-All II Sterile Packaging System

STERISs Vis-U-All II packaging products redefine quality by offering one of the highest grades of paper and polypropylene in the industry. The shatter resistant film and 45 pound paper, in combination with the triple seal makes the Vis-U-All II packaging system one of the most reliable sterility maintenance system available today. In addition, Vis-U-All II packaging utilises internal gas and steam chemical indicators creating a considerable sterility challenge. This product is also available in *Tyvek for use in ethylene oxide. Vis-U-All II Tyvek packaging is ideal for the sterilisation of rigid or sharp items that may puncture paper pouches. These pouches are available in heat seal, roll stock, and self-seaL The self-seal pouches feature a patented, no fold, flat seal design. Since there is no fold in the seal, there is no chance of Tunnel Fold Failure, which is common with other designs. *(Tyvek is a registered trademark of DuPont).
 
 




  EO Self ScanDaily Personnel Monitor, EO STELscan Short-Term Exposure Limit Monitor, and Xylene Personnel Monitors

The above Personnel Monitoring Systems provide onsite results for monitoring employees exposure to EO or xylene. These systems provide results the same day without leaving the work area. EO and xylene monitors can provide 8-hour, timeweighted average results as well as short-term exposure data, all meeting OSHA requirements for precision and accuracy.


ChemExpress Monitoring System

The ChemExpress Monitoring System is a mail-in monitoring service with reliable turnaround time. We perform the test, report the results, and retain and provide summary reports as needed. (All tests are prepaid.) Hands-off, hassle-free and OSHA Compliant.
 
 
  Biohazard Clear Bags

Made of strong plastic, these biohazard bags are autoclavable and suitable for steam sterilisation. They are printed with bold visuals signifying decontamination use.

 


 